Practice the dose ratio, Schild ordinate and a single-shift apparent affinity estimate, with the assumptions and limitations of competitive antagonism.

What a single shift can and cannot show

Under the simple reversible competitive, equilibrium, single-receptor model, the equieffective agonist concentration ratio r follows r − 1 = [B]/K_B, where [B] is the antagonist concentration in molar units. A Schild plot uses log10(r − 1) versus log10([B]). The empirical pA2 is the negative log molar antagonist concentration producing a twofold shift; it equals pK_B under the model assumptions.

A single pair of EC50 values cannot establish the Schild slope, prove competitive antagonism or independently establish pA2. The single-shift value below is an apparent pK_B conditional on the unit-slope model. Multiple antagonist concentrations and appropriately analyzed response curves are needed to assess consistency with that model; parallel shifts alone do not prove the mechanism.

Quantity for fictional inputsExpressionExample
Dose ratio1010 / 10101
Schild ordinatelog10(101 − 1)2
Apparent K_B in nM10^9 × 10^−7 / (101 − 1)1
Apparent pK_B−log10(10^−9 M)9

Calculate an apparent pK_B

B2 and B3 are control and shifted EC50 values in the same concentration units; B4 is the antagonist concentration in molar units. The example uses 10 and 1,010 nM and 10^−7 M. It calculates the logarithm using (B3 − B2)/B2 to avoid rounding the dose ratio before subtracting one.

The formula requires three positive numeric concentrations and B3 > B2. If a measured shift is 1 or less, log10(r − 1) is not defined as a real number; that result alone does not prove whether antagonism occurred. No patient dosing or clinical conclusion follows from this exercise.

=IF(ISTEXT(E2),E2,IFERROR(ROUND(LOG10((B3-B2)/B2)-LOG10(B4),4),"Values outside calculation range"))

Convert apparent K_B into nanomolar units

A molar estimate can be expressed in nM by multiplying by one billion. Values are not rounded before the conversion, so very small estimates are not silently rounded to zero.

=IF(ISTEXT(E2),E2,IFERROR(1000000000*B4*B2/(B3-B2),"Values outside calculation range"))

Try the example

Use the original values or change them to test your understanding.

Further reading