Desalination & Ultrapure Water Pretreatment, ASTM D4189 Reverse-Osmosis SDI-15
ASTM D4189 Reverse-Osmosis SDI-15 & Plugging Formula
Calculate Filtrate Time Ratio (ti / tf), 0.45-um Membrane Plugging Factor PF (%), ASTM D4189 Silt Density Index SDI-T, and % of 5.0 RO Membrane Warranty Ceiling.
Crystal-clear 0.3 NTU turbidity feedwater can still carry sub-micron colloidal silica that spikes SDI-15 past 5.0—blinding lead-element RO feed spacers and voiding membrane warranties
Optical nephelometers (NTU) barely scatter light off < 0.5 um colloidal clay, iron oxyhydroxide, and bacterial EPS—yet those exact colloids cake spiral-wound Polyamide Reverse-Osmosis (RO) Lead Elements. ASTM D4189 therefore measures dead-end filtration decay across a 47-mm, 0.45-um cellulose nitrate membrane disk regulated at 207 kPa (30.0 psi): timing t_i (seconds to collect the initial 500 mL) and t_f (seconds to collect a second 500 mL after T = 15 minutes of continuous flow) yields **Membrane Plugging Factor PF = (1 - (t_i / t_f)) * 100% and Silt Density Index SDI_T = PF / T (%/min). Spiral-wound RO manufacturers mandate SDI15 < 3.0 for low-fouling operation and SDI15 <= 5.0 absolute warranty ceiling** (furthermore, if PF > 75% during a 15-min run, ASTM D4189 invalidates linear SDI15 and requires switching to T = 5 min SDI_5).
Verify on Ultrafiltration (UF)-Pretreated Seawater RO Feed—Initial_500mL_Time t_i = 28.5 s (B2), Final_15min_500mL_Time t_f = 46.2 s (B3), and Elapsed_Interval T = 15.0 min (B4): Flow-Retention Ratio t_i / t_f equals 0.617 (E2), 0.45-um Plugging Factor PF equals 38.31% (<= 75% valid ASTM linear range. E3), SDI15 equals 2.55 (< 3.0 clean RO feed. E4), utilizing just 51.1% of the 5.0 RO warranty ceiling (E5).
| ASTM D4189 30-psi 0.45-um SDI KPI (ti=28.5 s, T=15 min) | Formula | Verified Output |
|---|---|---|
| Flow-Rate Retention Ratio (ti/tf) | Initial_500mL_ti_s / Final_500mL_tf_s | 0.617 (0.170 @ colloidal algae bloom) |
| Membrane Plugging Factor PF (%) | (1 - (ti_s / tf_s)) * 100 | 38.31% valid (83.04% > 75% PLUGGED) |
| ASTM Silt Density Index (SDI) | Plugging_Factor_PF_Pct / Interval_T_min | 2.55 CLEAN (<3.0) (5.54 > 5.0 FOULED) |
| % of 5.0 RO Warranty Max (%) | (ASTM_SDI_Index / 5.0) * 100 | 51.1% safe (110.7% WARRANTY VOID) |
ASTM D4189 0.45-um Dead-End Membrane Plugging & SDI-15 Formula
Validate Initial_Time t_i in [10, 120] s, Final_Time t_f >= t_i up to 1,200 s, and Test_Interval T in [5, 15] min.
=LET(ti_s, B2, tf_s, B3, tm_m, B4, pf_p, (1 - (ti_s / tf_s)) * 100, sd_i, pf_p / tm_m, IF(OR(ti_s < 10, ti_s > 120, tf_s < ti_s, tf_s > 1200, tm_m < 5, tm_m > 15), "Invalid SDI Input", ROUND((sd_i / 5) * 100, 1)))Broken UF Fiber / Coagulant Under-Dose (t_f = 168 s -> SDI_15 = 5.54) RO Blinding Check
Snap hollow-fiber UF capillaries or lose ferric chloride coagulant during a spring runoff event so final 500-mL collection drags out to B3 = 168.0 s: Plugging Factor E3 hits 83.04% (> 75% -> re-test as SDI_5) while SDI15 E4 climbs to 5.54 (110.7% of the 5.0 RO warranty max in E5)—commanding automatic feed diversion before irreversible colloidal cake locks lead RO vessels.
=IF(ISTEXT(E5), E5, ROUND(((1 - (B2 / B3)) * 100) / B4, 2))Try the example
Use the original values or change them to test your understanding.