Arte SheetsLearn. Try. Understand.

Brewing, Cider & Packaged Beverage Engineering, Del Vecchio Tunnel Pasteurization Units (PU)

Brewery Tunnel Pasteurization Units (PU) Lethality Formula

Calculate Del Vecchio Instantaneous Pasteurization Rate 1.393^(T-60) (PU/min), Total Delivered PU, Minimum Hold Time for Target PU (min), and Spec Realization (%).

A 32-minute filler line jam inside a 64.5°C tunnel pasteurizer cooks canned lager to 142 PU—turning crisp hops into wet-cardboard trans-2-nonenal

Unlike low-acid canned vegetables (pH > 4.6, sterilized at 121.1°C with z = 10°C for *C. botulinum* F_0), alcoholic beer (pH 4.1–4.4, ethanol + hop iso-alpha acids) and sparkling ciders only need gentle 60–65°C heat to kill spoilage *Lactobacillus*, *Pediococcus*, and wild *Saccharomyces*. Del Vecchio, Dayharsh & Baselt (ASBC / EBC Standard) defined 1 Pasteurization Unit (1 PU) as 1 minute at 60.0°C with thermal resistance z = 6.94°C (~7.0°C) (10^(1 / 6.94) = 1.393), giving InstantaneousPU Lethality Rate LPU = 1.393^(T - 60) (PU/min) and **Cumulative Hold-Zone Lethality PU = t * 1.393^(T - 60) across Cold-Spot Hold Time t (min) at Core Temperature T (°C). Pale lagers target 15–25 PU**: below 15 PU risks bottle-refermentation gushing; above 40–50 PU accelerates Maillard/lipid oxidation ("papery/breadcrust" flavor staling) and blows crowns.

Verify on a 355 mL Canned Pilsner Walking-Beam Tunnel Pasteurizer—Cold-Spot_Hold_Temp T = 62.5°C (B2), Hold_Zone_Dwell t = 11.0 min (B3), and Brewery_Target PUspec = 22.0 PU (B4): Lethal Rate LPU equals 2.290 PU/min (E2), Delivered PU equals 25.19 PU (E3), Minimum Hold Time for 22 PU equals 9.61 min (E4), achieving 114.5% of target lethality without heat damage (E5).

EBC / ASBC Tunnel Pasteurizer KPI (Target = 22.0 PU, Reference T0 = 60°C, z = 6.94°C)FormulaVerified Output
Lethal Rate L_PU (PU / min)1.393 ^ (Cold_Spot_Temp_C - 60)2.290 PU/min @ 62.5°C (4.444 @ 64.5°C)
Total Delivered Lethality (PU)Hold_Time_min * (1.393 ^ (Temp_C - 60))25.19 PU (142.21 PU BAKED BEER @ jam)
Min Hold Time for Spec (min)Target_Spec_PU / (1.393 ^ (Temp_C - 60))9.61 min (4.95 min @ 64.5°C)
Target PU Realization (%)(Delivered_PU / Target_Spec_PU) * 100114.5% optimal (646.4% oxidized)

Del Vecchio ASBC / EBC PU = t * 1.393^(T - 60) Beverage Lethality Formula

Validate pasteurizing Core_Temp T in [50, 80]°C, Hold_Time t in (0, 180] min, and Target_PU in [5, 200] PU.

=LET(tc_p, B2, th_m, B3, pu_s, B4, lr_p, 1.393 ^ (tc_p - 60), IF(OR(tc_p < 50, tc_p > 80, th_m <= 0, th_m > 180, pu_s < 5, pu_s > 200), "Invalid PU Input", ROUND(((th_m * lr_p) / pu_s) * 100, 1)))

Downstream Labeler Stoppage Without Spray Attemperation (T = 64.5°C, t = 32 min) Staling Check

Stall the tunnel conveyor for B3 = 32 minutes while spray headers drift up to B2 = 64.5°C without cold-water PU-control dousing: Lethal Rate E2 nearly doubles (4.444 PU/min) and Delivered PU E3 explodes to 142.21 PU (646.4% of spec in E5)—forcing QA sensory hold and automatic cold-spray cooling-loop interlocks.

=IF(ISTEXT(E5), E5, ROUND(B3 * (1.393 ^ (B2 - 60)), 2))

Try the example

Use the original values or change them to test your understanding.

Further reading