Engineering & Science
Bloch-Grüneisen Metal Resistivity: T^5 Cryogenic vs Linear High-T Law
Explore low- and high-temperature approximations to the Bloch–Grüneisen model and use the full integral in the crossover region.
Two asymptotic approximations, with a crossover between them
The Bloch–Grüneisen model describes a phonon-scattering contribution through an integral. Its low-temperature T^5 and high-temperature expansions are approximations at opposite ends of the temperature range; neither should be used uncritically in the middle. The coefficients below use the particular normalization shown in this example.
For the illustrative inputs rho_0 = 0.0020 μΩ·cm, Θ_R = 333 K and rho_Θ = 1.88 μΩ·cm, the low-T expression gives approximately 0.002731 μΩ·cm at 20 K, while the high-T expansion gives approximately 1.5798 μΩ·cm at 300 K. These are model calculations, not measured values or material-design guarantees.
The exercise uses deliberately conservative gates of T ≤ 0.07 Θ_R for the low-T limit and T ≥ 0.5 Θ_R for the displayed high-T expansion. Between them it asks for the full integral. The gates are examples, not universal accuracy guarantees; validate the full model, fitted coefficients and tolerances for the material and intended use.
| Temperature | Model used in this exercise | Approximate result |
|---|---|---|
| 20 K | Low-T limit | 0.002731 μΩ·cm |
| 100 K | Crossover — use full integral | No asymptotic result |
| 300 K | Truncated high-T expansion | 1.5798 μΩ·cm |
| 600 K | Truncated high-T expansion | 3.3314 μΩ·cm |
High-temperature expansion (illustrative gate: T ≥ 0.5 Θ_R)
This truncated expression approaches the full model as temperature rises. Its error is nonzero and depends on T/Θ_R; below the stated gate, evaluate the full integral instead of automatically substituting the low-T limit.
=IF(COUNT(B2:B5)<>4,"Invalid BG inputs",IF(OR(B2<0,B3<=0,B4<=0,B5<=0),"Invalid BG inputs",IF(B5<0.5*B3,"Below high-T range; evaluate the full integral",ROUND(B2+B4*(B5/B3)*(1-B3^2/(18*B5^2)),4))))Low-temperature T^5 limit (illustrative gate: T ≤ 0.07 Θ_R)
The low-T expression uses 4 × 124.4 ≈ 497.6 for the integral’s low-temperature limit under this normalization. The formula explicitly rejects temperatures outside its chosen low-T gate.
=IF(COUNT(B2:B5)<>4,"Invalid BG inputs",IF(OR(B2<0,B3<=0,B4<=0,B5<=0),"Invalid BG inputs",IF(B5>0.07*B3,"Outside low-T range; evaluate the full integral",ROUND(B2+497.6*B4*(B5/B3)^5,6))))Try the example
Use the original values or change them to test your understanding.