Arte SheetsLearn. Try. Understand.

Robotics, UAV Propulsion & Electric Drivetrain Engineering, BLDC Motor Kv & Kt Physics

BLDC Motor Kv Constant, Torque Kt & Shaft Power Formula

Calculate Exact SI Torque Constant Kt = 60 / (2*PI()*Kv) (N·m/A), Electromagnetic Torque (N·m), Resistive Voltage-Drop Loaded Speed (RPM), and Mechanical Shaft Power (kW).

Higher Kv NEVER means "more powerful"—by Lorentz-Faraday reciprocity, doubling BLDC Kv cuts torque per amp Kt in HALF

Drone builders, e-foil designers, and robotics engineers select Permanent-Magnet Brushless DC (BLDC) Motors by Velocity Constant K_v (RPM / Volt unloaded), yet routinely guess torque. By exact SI conservation of electrical and mechanical power (Ebemf * I = tau * omega), Torque Constant K_t (N·m/A) is strictly the reciprocal of K_v expressed in rad/(s·V): **K_t = 60 / (2 * PI() * K_v) ~= 9.5493 / K_v (N·m/A). Driven from DC Bus Voltage Vbus (V) across Winding Resistance Rll (Ohm) at Motor Current I (A), Electromagnetic Torque tau = K_t * I** (N·m) comes at the expense of Ohmic I * Rll voltage drop, pulling **Loaded Shaft Speed down linearly along the torque-speed line N = K_v * (Vbus - I * Rll) (RPM) and delivering Mechanical Shaft Power Pmech = (tau * N * 2 * PI() / 60) / 1,000** (kW).

Verify on a 420 Kv 48 V Heavy-Lift Cargo Drone / Robotics Actuator Outrunner—Motor_Velocity_Constant K_v = 420 RPM/V (B2 -> unloaded 20,160 RPM), DC_Bus_Voltage Vbus = 48.0 V (B3), Terminal_Resistance Rll = 0.065 Ohm (B4), and Cruise_Current I = 55.0 A (B5): Exact SI Torque Constant K_t equals 0.02274 N·m/A (22.74 mN·m/A, E2), Cruise Torque equals 1.25 N·m (E3), Loaded Speed drops to 18,658.5 RPM (3.575 V I*R drop, E4), delivering 2.44 kW mechanical shaft power (E5).

BLDC Drivetrain KPI (420 Kv, 48 V Bus, R=0.065 Ohm: 55 A Cruise vs 160 A Climb Burst)FormulaVerified Output
SI Torque Constant Kt (N·m/A)60 / (2 * PI() * Motor_Kv_RPM_V)0.02274 N·m/A (exact 9.5493 / Kv)
Electromagnetic Torque (N·m)Kt_Nm_A * Motor_Current_A1.25 N·m (3.64 N·m @ 160 A burst)
Loaded Shaft Speed N (RPM)Motor_Kv * (Bus_V - Current_A * Resist_Ohm)18,658.5 RPM (15,792.0 RPM @ 160 A droop)
Mechanical Shaft Power (kW)(Torque_Nm * Loaded_RPM * 2*PI()/60) / 10002.44 kW (6.02 kW + 1.66 kW I²R copper heat)

Lorentz-Faraday BLDC Kv-to-Kt Reciprocity, Speed Droop & Shaft Power Formula

Validate Motor K_v in [10, 15,000] RPM/V, Bus_Voltage Vbus in [3, 1,000] V, Resistance Rll > 0 Ohm, and Current I >= 0 below locked-rotor stall (I * Rll < Vbus).

=LET(kv_r, B2, vb_v, B3, rl_o, B4, im_a, B5, kt_n, 60 / (2 * PI() * kv_r), tq_n, kt_n * im_a, nr_p, kv_r * (vb_v - im_a * rl_o), IF(OR(kv_r < 10, kv_r > 15000, vb_v < 3, vb_v > 1000, rl_o <= 0, im_a < 0, im_a * rl_o >= vb_v), "Invalid BLDC Input", ROUND((tq_n * nr_p * 2 * PI() / 60) / 1000, 2)))

160 A Full-Throttle Climb Burst Copper Droop Check (Set Current B5 = 160 A)

Command 160 A peak ESC phase current (B5 = 160): Torque E3 triples to 3.64 N·m and Mechanical Output E5 hits 6.02 kW, YET resistive drop (160 * 0.065 = 10.4 V) drags Loaded Speed E4 down 21.7% below unloaded RPM to 15,792.0 RPM while dumping I^2 * R = 1,664 W of copper heat straight into the stator windings.

=IF(ISTEXT(E5), E5, ROUND(B2 * (B3 - B5 * B4), 1))

Try the example

Use the original values or change them to test your understanding.

Further reading