Arte SheetsLearn. Try. Understand.

Vacuum & Torch Brazing Metallurgy, AWS C3.4 Capillary Joint Overlap & Wicking Rise

Capillary Brazing Joint Overlap & Wicking Rise Formula

Calculate AWS Required Braze Overlap Length (mm), Overlap-to-Thickness Ratio (L/t), Molten Filler Capillary Suction Pressure (kPa), and Vertical Wicking Height (mm).

Widen a furnace-braze joint clearance from 0.06 mm to a sloppy 0.45 mm and molten silver/copper filler loses 87% of its vertical capillary climb

Vacuum and Controlled-Atmosphere Furnace Brazing (AWS C3.4 / Brazing Handbook) joins stainless heat exchangers, carbide rock bits, and rocket injectors WITHOUT melting base metal of Thickness t (mm) and Ultimate Tensile Strength sigmaut (MPa). To ensure the base metal yields in tension *before* the thin filler layer (Shear Strength taubraze MPa) shears at Safety Factor FS (~3.0), joint designers size **Minimum Lap Length Llap = (FS * sigmaut * t) / taubraze (mm, generalizing the shop-floor "3t rule"). Crucially, molten BAg silver or BCu copper filler (Surface Tension gamma N/m, Wetting Angle theta < 25°, Liquid Density rho kg/m³) climbs upward into Parallel-Wall Clearance w (mm, optimal 0.025–0.10 mm) solely by Capillary Suction Delta_P_c = (2 * gamma * COS(theta)) / (w / 1,000) (Pa), reaching Maximum Vertical Wicking Height hwick = ((2 * gamma * COS(theta)) / (rho * 9.80665 * (w / 1,000))) * 1,000** (mm).

Verify on a 2.0 mm 316L Stainless Plate-Fin Vacuum Braze Joint—Base_Sheet_Gauge t = 2.00 mm (B2), Base_Tensile sigmaut = 420 MPa (B3), BAg-7_Braze_Shear taubraze = 175 MPa (B4), Safety_Factor FS = 3.0 (B5 -> Required Overlap Llap = 14.40 mm = 7.20 * t in E2 & E3), Hot_Joint_Gap w = 0.06 mm (B6), Molten_Surface_Tension gamma = 1.05 N/m (B7), Fluxless_Vacuum_Wetting theta = 18.0° (B8), and Molten_Filler_Density rho = 8,600 kg/m³ (B9): Capillary Pressure reaches 33.29 kPa (E4), wicking molten silver 394.7 mm straight up against gravity (E5).

AWS Furnace Brazing KPI (t=2.0 mm, UTS=420, tau=175 MPa, FS=3.0, Gap w=0.06 vs 0.45 mm)FormulaVerified Output
Required Braze Overlap L_lap (mm)(FS * Base_UTS_MPa * Thick_mm) / Braze_Shear14.40 mm
Overlap-to-Thickness Ratio (L/t)Required_Overlap_mm / Sheet_Thick_t_mm7.20 x sheet thickness
Capillary Suction Pressure (kPa)((2 * gamma * COS(rad)) / (w_mm / 1000)) / 100033.29 kPa (4.44 kPa @ sloppy 0.45 mm gap)
Vertical Wicking Rise h_wick (mm)((2*gamma*COS(rad))/(rho*9.80665*(w/1000)))*1e3394.7 mm (52.6 mm void starvation @ 0.45 mm)

AWS Lap-Shear Strength Balance & Parallel-Slot Capillary Wicking Formula

Validate Thickness t > 0.1 mm, Base_UTS > 50 MPa, Braze_Shear > 20 MPa, FS >= 1.0, Joint_Gap w in [0.01, 2.00] mm, Surface_Tension gamma in [0.2, 2.5] N/m, wetting theta in [0°, 75°], and Molten_Density in [2,000, 18,000] kg/m³.

=LET(ts_m, B2, ut_m, B3, tb_m, B4, fs_j, B5, wg_m, B6 / 1000, gm_n, B7, th_r, B8 * (PI() / 180), rm_k, B9, IF(OR(ts_m <= 0.1, ut_m <= 50, tb_m <= 20, fs_j < 1, B6 < 0.01, B6 > 2, gm_n < 0.2, gm_n > 2.5, B8 < 0, B8 > 75, rm_k < 2000, rm_k > 18000), "Invalid Braze Joint", ROUND(((2 * gm_n * COS(th_r)) / (rm_k * 9.80665 * wg_m)) * 1000, 1)))

Out-of-Tolerance 0.45 mm Machined Socket Gap Void Starvation Check (Set Gap w B6 = 0.45 mm)

Machine a loose 0.45 mm slip fit (B6 = 0.45) instead of 0.06 mm: Capillary Suction E4 collapses from 33.29 to 4.44 kPa and Vertical Wicking Height E5 plunges from 394.7 down to 52.6 mm—draining molten braze out the bottom of tall heat-exchanger sleeves and leaving unbonded leak paths.

=IF(ISTEXT(E5), E5, ROUND((B5 * B3 * B2) / B4, 2))

Try the example

Use the original values or change them to test your understanding.

Further reading