Geotechnical Dewatering & Slope Stabilization, Casagrande Electro-Osmosis in Soft Clays
Casagrande Electro-Osmotic Clay Dewatering & Power Formula
Calculate Electric Voltage Gradient ie = V/L (V/m), Electro-Osmotic Cathode Water Flow Qe (L/h), DC Rectifier Ohmic Power (kW), and Specific Dewatering Energy (kWh/m³).
Vacuum wellpoints fail completely in fat marine clay (k_h = 10^-10 m/s)—yet a 50 V/m DC electric field pumps pore water 10,000x faster
Hydraulic conductivity k_h collapses with grain diameter squared (10^{-9} to 10^{-11} m/s in soft sensitive clays and silts, rendering gravity/vacuum wells useless). Leo Casagrande discovered that **Coefficient of Electro-Osmotic Permeability k_e is remarkably constant (~4.0–6.0 * 10^{-9} m²/(s·V)) across almost ALL fine soils because mobile hydrated cations inside negatively charged clay double-layers drag pore water from steel/EKG Anodes (+) into pumped Cathode Wells (-). Applying DC Voltage V across Electrode Spacing L (m -> Electric Field i_e = V / L V/m) over Cross-Sectional Clay Area A (m²) drives Electro-Osmotic Flow Q_e = k_e * i_e * A** (m³/s, * 3.6 * 10^6 = L/h), while Bulk Soil Electrical Conductivity sigma_e (S/m) dissipates **DC Rectifier Power PDC = (sigma_e * (V^2 / L) * A) / 1,000 (kW)—revealing that Specific Energy E_w = PDC / Qe,m3/h (kWh/m³) scales linearly with V!**
Verify on a Sensitive Marine-Clay Excavation Cut Stabilization—DC_Rectifier_Voltage V = 90.0 V (B2), Anode-to-Cathode_Spacing L = 1.80 m (B3 -> Voltage Gradient i_e = 50.0 V/m in E2), Electro-Osmotic_Permeability k_e = 5.0 (x 10^-9 m²/(s·V), B4), Treated_Cross-Section A = 24.0 m² (B5), and Pore-Fluid_Clay_Conductivity sigma_e = 0.085 S/m (B6): Pumped Cathode Seepage reaches 21.60 L/h (E3), DC Power draws 9.18 kW (E4), and Specific Energy equals 425.0 kWh/m³ of extracted pore water (E5).
| Casagrande Electro-Osmosis KPI (L=1.8 m, ke=5.0e-9, A=24 m², sigma=0.085 S/m, V=90 vs 140 V) | Formula | Verified Output |
|---|---|---|
| Electric Field Gradient ie (V/m) | DC_Voltage_V / Electrode_Spacing_L_m | 50.0 V/m (77.8 V/m desiccation risk @ 140 V) |
| Cathode Water Extraction Qe (L/h) | (ke_e9 * 1e-9) * ie * Area_m2 * 3,600,000 | 21.60 L/h (33.60 L/h @ 140 V) |
| DC Rectifier Load P_DC (kW) | (sigma_S_m * (V^2 / L_m) * Area_m2) / 1000 | 9.18 kW (22.21 kW = V^2 Ohmic heating) |
| Specific Dewatering Energy (kWh/m³) | DC_Power_kW / (Water_Flow_L_h / 1000) | 425.0 kWh/m³ (661.1 kWh/m³ @ 140 V) |
Casagrande Electro-Osmotic Seepage Law & Ohmic Soil Heating Power Formula
Validate DC_Voltage V in [10, 250] V, Spacing L in [0.5, 6.0] m, k_e in [0.5, 15.0] (x 10^-9), Area A > 1 m², and Conductivity sigma_e in [0.005, 1.50] S/m.
=LET(vd_c, B2, ls_m, B3, ke_n, B4 * 0.000000001, ac_m, B5, sg_s, B6, ie_v, vd_c / ls_m, qe_m, ke_n * ie_v * ac_m * 3600, pk_w, (sg_s * (vd_c ^ 2) * ac_m) / (ls_m * 1000), IF(OR(vd_c < 10, vd_c > 250, ls_m < 0.5, ls_m > 6, B4 < 0.5, B4 > 15, ac_m <= 1, sg_s < 0.005, sg_s > 1.5), "Invalid EO Input", ROUND(pk_w / qe_m, 1)))Excessive 140 V Anode Heating & V^2 Power Penalty Check (Set DC Voltage B2 = 140 V)
Boost rectifier voltage from 90 to 140 V (B2 = 140, Field Gradient E2 = 77.8 V/m > 60 V/m Casagrande anode-drying ceiling): Water Flow E3 rises +55.6% to 33.60 L/h, YET DC Power E4 jumps +142% ((140/90)^2) to 22.21 kW and Specific Energy E5 climbs to 661.1 kWh/m³—baking and cracking clay around the anodes so electrical contact resistance spikes.
=IF(ISTEXT(E5), E5, ROUND((B6 * (B2 ^ 2) * B5) / (B3 * 1000), 2))Try the example
Use the original values or change them to test your understanding.