Arte SheetsLearn. Try. Understand.

Structural Engineering, TMS 402 Reinforced CMU Masonry Walls & Buckling Slenderness

CMU Masonry Wall Prism Strength & Slenderness Formula

Calculate Masonry Wall Slenderness Ratio h/r, TMS 402 Piecewise Parabolic-to-Euler Buckling Reduction Factor, Nominal Axial Capacity Pn (kN), and LRFD Strength phi*Pn (kN).

Cross h/r = 99 on a tall warehouse CMU block wall and TMS 402 switches from parabolic crushing to inverse-square Euler buckling

Reinforced concrete masonry unit (CMU) warehouse and gymnasium bearing walls are governed by Specified Masonry Prism Compressive Strength f’_m (MPa, tested per ASTM C1314 on mortared/grouted block prisms), Effective Net Cross-Sectional Area A_n (mm²/m of wall length), Unbraced Clear Height h (mm), and Section Radius of Gyration r = SQRT(I_n / A_n) (mm, ~58 mm for a fully grouted 190 mm nominal 8-inch CMU wall). Under TMS 402 / ACI 530 Strength Design, Slenderness Ratio h / r triggers a sharp two-branch piecewise buckling reduction factor R_s: for h / r <= 99, parabolic inelastic crushing governs R_s = 1 - ((h / r) / 140)^2; for slender tall walls h / r > 99, elastic Euler column buckling governs R_s = (70 / (h / r))^2. Multiplying by 0.80 eccentricity-tie factor and 0.80 * f’_m * A_n yields **Nominal Axial Strength P_n = (0.80 * (0.80 * f’_m * A_n) * R_s) / 1,000 (kN) and LRFD Design Strength phi * P_n** (phi = 0.90).

Verify on a 190 mm Fully Grouted CMU Bearing Wall (1 m strip)—Prism_Strength f’_m = 13.8 MPa (2,000 psi, B2), Grouted_Net_Area A_n = 190,000 mm²/m (B3), Unbraced_Wall_Height h = 4,200 mm (B4), and Radius_of_Gyration r = 58.0 mm (B5): h / r equals 72.41 <= 99 (E2), Parabolic Slenderness Factor equals 0.7325 (E3), Nominal P_n reaches 1,229.1 kN/m (E4), and LRFD phi * P_n equals 1,106.2 kN/m (E5). Note on external AI review workflows: if your structural team tests scoped OAuth workbook inspection through the Arte Sheets ChatGPT plugin 0.1.0 (currently In review / Not published), remember that read_range (<= 200 cells) inspects raw formulas and stored values on cloud collaboration workbooks without recalculating results—always verify both branches (h / r <= 99 and > 99) directly in the live sheet.

TMS 402 Reinforced CMU Wall KPI (fm=13.8 MPa, An=190,000 mm², r=58 mm, h=4.2 vs 6.2 m)FormulaVerified Output
Wall Slenderness Ratio (h / r)Unbraced_Height_h_mm / Radius_Gyration_r_mm72.41 (106.90 > 99 Euler @ h=6,200 mm)
TMS 402 Slenderness Factor RsIF(h/r<=99, 1-(h/(140*r))^2, (70/(h/r))^2)0.7325 (0.4288 @ h=6,200 mm)
Nominal Axial Capacity Pn (kN/m)(0.80 * (0.80 * fm * An) * Rs) / 10001,229.1 kN/m (719.6 kN/m @ h=6,200 mm)
LRFD Design Capacity phi*Pn (kN/m)0.90 * Nominal_Pn_kN1,106.2 kN/m (647.6 kN/m = -41.5% drop)

TMS 402 Piecewise Slenderness Transition (h/r = 99) & Axial LRFD Formula

Validate Prism_Strength f’_m in [5, 45] MPa, Net_Area A_n > 10,000 mm², Height h >= 1,000 mm, and Radius_of_Gyration r > 15 mm.

=LET(fm_p, B2, an_m, B3, hw_m, B4, rg_m, B5, hr_r, hw_m / rg_m, pc_k, (0.8 * (0.8 * fm_p * an_m)) / 1000, IF(OR(fm_p < 5, fm_p > 45, an_m <= 10000, hw_m < 1000, rg_m <= 15), "Invalid Masonry Input", ROUND(0.9 * pc_k * IF(hr_r <= 99, 1 - ((hr_r / 140) ^ 2), (70 / hr_r) ^ 2), 1)))

High-Bay 6.2 m Big-Box Retail Wall Euler Buckling Transition Check (Set Wall Height B4 = 6,200 mm)

Raise clear roof-ledger height from 4,200 to 6,200 mm (B4 = 6200) without thickening the 190 mm block core: h / r E2 crosses 99 to 106.90, switching E3 onto the inverse-square Euler curve (R_s = 0.4288) and cutting LRFD Design Strength E5 by -41.5% to 647.6 kN/m—signaling an upgrade to 240 or 290 mm (10- or 12-inch) CMU pilasters.

=IF(ISTEXT(E5), E5, LET(hr_r, B4 / B5, ROUND(IF(hr_r <= 99, 1 - ((hr_r / 140) ^ 2), (70 / hr_r) ^ 2), 4)))

Try the example

Use the original values or change them to test your understanding.

Further reading