Hydrometallurgy & Electrochemical Refining, Copper SX-EW Tankhouse Faraday Balance
Copper Electrowinning Tankhouse Harvest & kWh/t Formula
Calculate Daily LME Grade-A Copper plated per Electrolytic Cell (kg/day), Total Tankhouse Cathode Harvest (t/day), Rectifier DC Bus Load (MW), and Specific DC Energy (kWh/t Cu).
Ferric iron Fe³⁺ carryover from solvent extraction parasitic-redoxes copper cathodes—dropping current efficiency from 92.5% to 78% and spiking power cost +31%
In Solvent-Extraction Electrowinning (SX-EW) copper hydrometallurgy, rich CuSO_4 - H_2SO_4 pregnant electrolyte circulates through Ncell Polymer-Concrete Electrolytic Cells wired electrically in series at Rectifier DC Current I (kA), plating 99.99% LME Grade-A copper (MCu = 63.546 g/mol, n = 2 electrons per Cu²⁺ ion, Faraday constant F = 96,485.332 C/mol) onto 316L stainless-steel mother blanks opposite Pb-Ca-Sn oxygen-evolving anodes (Cell Voltage Vcell ~= 1.95–2.25 V vs 0.89 V thermodynamic decomposition). By Faraday’s Law scaled by Cathodic Current Efficiency eta_I% (lost to Fe³⁺ + e⁻ -> Fe²⁺ parasitic iron shuttle and stray short circuits), each cell plates **mcell = ((I * 1,000) * 86,400 * 63.546 * (eta_I / 100)) / (2 * 96,485.332 * 1,000) (kg Cu/day), totaling Mtot = (mcell * Ncell) / 1,000 (t Cu/day) at Specific DC Energy Espec = (Vcell * 2 * 96,485.332 * 1,000) / (3,600 * 63.546 * (eta_I / 100))** (kWh/t Cu).
Verify on an 84-Cell Commercial SX-EW Tankhouse Section—Rectifier_DC_Current I = 34.0 kA (B2), Series_Electrolytic_Cells Ncell = 84 (B3), Cathodic_Current_Efficiency eta_I = 92.5% (B4), and Mean_Cell_Voltage Vcell = 2.02 V (B5): Copper Plated per Cell equals 894.81 kg/day (E2), Total Section Harvest equals 75.16 t Cu/day (E3), Rectifier DC Bus Load equals 5.769 MW (E4), and Specific Energy equals 1,842.1 kWh/t Cu (E5).
| SX-EW Tankhouse Faraday KPI (34 kA, 84 Series Cells: Clean Electrolyte vs High-Fe³⁺) | Formula | Verified Output |
|---|---|---|
| Daily Copper per Cell (kg/day) | (I_kA*1e3 * 86400 * 63.546 * CE) / (2 * 96485.332 * 1e3) | 894.81 kg/d (754.54 kg/d @ 78% CE) |
| Tankhouse Cathode Harvest (t/day) | (Daily_Cu_Cell_kg * Series_Cells_N) / 1000 | 75.16 t/d (63.38 t/d = -11.8 t/d lost) |
| Rectifier DC Bus Power (MW) | (Current_kA * Series_Cells_N * Vcell_V) / 1000 | 5.769 MW (6.397 MW @ scaled anodes) |
| Specific DC Energy (kWh/t Cu) | (Rectifier_MW * 24 * 1000) / Harvest_t_d | 1,842.1 kWh/t (2,422.4 kWh/t = +31.5%) |
Faraday Divalent Cu²⁺ Electrowinning Mass Balance & Specific Energy Formula
Validate Rectifier_Current I in [1, 100] kA, integer Series_Cells Ncell in [1, 500], Current_Efficiency in [40%, 100%], and Cell_Voltage Vcell in [1.50, 3.50] V.
=LET(ik_a, B2, nc_s, B3, ce_p, B4, vc_v, B5, mc_k, (ik_a * 1000 * 86400 * 63.546 * (ce_p / 100)) / (2 * 96485.332 * 1000), mt_t, (mc_k * nc_s) / 1000, mw_d, (ik_a * nc_s * vc_v) / 1000, IF(OR(ik_a < 1, ik_a > 100, nc_s < 1, nc_s > 500, ce_p < 40, ce_p > 100, vc_v < 1.5, vc_v > 3.5), "Invalid EW Input", ROUND((mw_d * 24 * 1000) / mt_t, 1)))High Ferric Entrainment + Anode Scale (CE = 78%, V_cell = 2.24 V) Power-Penalty Check
Let crud carryover spike electrolyte Fe³⁺ > 3 g/L (CE drops to B4 = 78%) while aged lead anodes climb to B5 = 2.24 V: Daily Harvest E3 loses 11.78 tonnes/day (75.16 -> 63.38 t/d) even as Rectifier Power E4 rises to 6.397 MW—driving Specific Energy E5 up +31.5% to 2,422.4 kWh/t Cu.
=IF(ISTEXT(E5), E5, LET(mc_k, (B2 * 1000 * 86400 * 63.546 * (B4 / 100)) / (2 * 96485.332 * 1000), ROUND((mc_k * B3) / 1000, 2)))Try the example
Use the original values or change them to test your understanding.