Arte SheetsLearn. Try. Understand.

Cryogenic Air Separation & Gas Liquefaction, Joule-Thomson & Linde-Hampson (1895) Cycle

Joule-Thomson Cooling & Linde-Hampson Liquefaction Formula

Calculate Isenthalpic Joule-Thomson Temperature Drop (K), Warm-End Isothermal Enthalpy Deficit (kJ/kg), Linde-Hampson Liquid Yield Fraction (%), and Liquid Nitrogen Production (kg/h).

Throttling 200-bar nitrogen drops 36.8 K across a single Joule-Thomson valve—yet without Carl von Linde’s counterflow recuperator, 0% condenses until warm-end enthalpy deficit locks in 11.87% liquid yield

When compressed real gas (Nitrogen or Air below its 621 K inversion curve—unlike 300 K H_2 or He, which *heat up* upon throttling unless pre-cooled below 202 K and 40 K) expands adiabatically through a porous plug or needle valve (dh = 0), intermolecular van der Waals attraction produces **Joule-Thomson Cooling Delta_TJT = muJT * (P_2 - P_1) (K across Mean J-T Coefficient muJT K/bar). Carl von Linde and William Hampson (1895) turned that modest single-pass drop into continuous 77.4 K liquefaction by routing un-liquefied cold flash vapor (1 - y) back through a counterflow recuperator. Applying a control-volume energy balance around the cold box (Warm Low-Pressure Exit Enthalpy h_1 kJ/kg, Warm High-Pressure Inlet Enthalpy h_2 kJ/kg, and Saturated Liquid Enthalpy h_f kJ/kg) proves Liquid Yield Fraction y = ((h_1 - h_2) / (h_1 - h_f)) * 100% depends ENTIRELY on the Warm-End Isothermal Real-Gas Enthalpy Deficit (h_1 - h_2)** compressed into P_2.

Build this Cryogenic Cold-Box Balance Sheet—Compressor_Discharge P_2 = 200 bar (B2), Separator_Return P_1 = 1.013 bar (B3), Mean_muJT = 0.185 K/bar (B4), Low-Pressure_Warm_Gas h_1 = 301.5 kJ/kg (B5), 200-bar_Warm_Gas h_2 = 269.2 kJ/kg (B6), 77.4-K_Saturated_LN_2 h_f = 29.4 kJ/kg (B7), and Recycle_Compressor_Flow mdot = 140 kg/h (B8). Ask the in-app assistant for a first-law control-volume hint before writing the cell formulas: Initial J-T Valve Drop equals 36.81 K (E2), Warm Isothermal Enthalpy Deficit h_1 - h_2 equals 32.30 kJ/kg (E3), Steady-State Linde-Hampson Liquid Yield equals 11.87% (E4), producing 16.62 kg/h of LN_2 (E5).

Linde-Hampson N2 Liquefier KPI (300 K Warm End: h1=301.5, hf=29.4 kJ/kg, m=140 kg/h)FormulaVerified Output
Single-Pass J-T Temp Drop (K)Mean_JT_K_bar * (High_P2_bar - Low_P1_bar)36.81 K @ 200 bar (19.74 K @ 95 bar)
Isothermal Enthalpy Deficit (kJ/kg)LowP_Warm_h1_kJ_kg - HighP_Warm_h2_kJ_kg32.30 kJ/kg (16.90 kJ/kg @ 95 bar)
Linde-Hampson Liquid Yield (%)((h1 - h2) / (h1 - Sat_Liq_hf)) * 10011.87% yield (6.21% @ 95 bar sag)
Liquid LN2 Production (kg/h)Compressor_kg_hr * ((h1 - h2) / (h1 - hf))16.62 kg/h (8.70 kg/h halved output)

Linde-Hampson (1895) Cold-Box Control-Volume Enthalpy & J-T Liquefaction Formula

Validate High_Pressure P_2 in [20, 400] bar, Low_Pressure P_1 in [0.8, 10] bar (with P_2 > P_1 + 15), Mean muJT in [0.02, 1.50] K/bar, Enthalpies h_f < h_2 < h_1 (kJ/kg), and Mass_Flow > 0 kg/h.

=LET(ph_b, B2, pl_b, B3, mj_k, B4, hl_k, B5, hh_k, B6, hf_k, B7, mf_h, B8, yx_f, (hl_k - hh_k) / (hl_k - hf_k), IF(OR(ph_b < 20, ph_b > 400, pl_b < 0.8, pl_b > 10, ph_b <= pl_b + 15, mj_k < 0.02, mj_k > 1.5, hf_k >= hh_k, hh_k >= hl_k, mf_h <= 0), "Invalid Linde Input", ROUND(mf_h * yx_f, 2)))

Derated Final Compressor Stage (P_2 = 95 bar -> h_2 = 284.6 kJ/kg) Yield-Halving Check

Bypass a leaking 4th-stage piston ring so discharge pressure drops to B2 = 95.0 bar (muJT B4 = 0.210 K/bar, h_2 rises to B6 = 284.6 kJ/kg): Warm Enthalpy Deficit E3 shrinks from 32.30 down to 16.90 kJ/kg, cutting Liquid Yield E4 nearly in half to 6.21% (8.70 kg/h LN_2 in E5)—proving why industrial plants add Claude expansion turbines or NH3 pre-cooling.

=IF(ISTEXT(E5), E5, ROUND(((B5 - B6) / (B5 - B7)) * 100, 2))

Try the example

Use the original values or change them to test your understanding.

Further reading