Arte SheetsLearn. Try. Understand.

Renewable Wind Energy & Distributed Aerodynamics, Darrieus Lift vs Savonius Drag VAWT

Darrieus & Savonius VAWT Solidity, TSR & Torque Formula

Calculate Vertical-Axis Wind Turbine Blade Chord Solidity (N*c/R), Tip-Speed Ratio lambda, Rectangular Swept-Area Shaft Power (kW), and Aerodynamic Rotor Torque (N·m).

Why low-solidity Darrieus H-rotors capture 2x the wind power of Savonius S-buckets—yet cannot self-start without starter torque at TSR < 1

Vertical-Axis Wind Turbines (VAWTs) accept omnidirectional turbulent rooftop/offshore wind without yaw drives across a **Rectangular Swept Area A = 2 * R * H (m², where R is Rotor Radius m and H is Vertical Blade Span m), splitting into two opposite aerodynamic regimes governed by Rotor Chord Solidity sigma = (N * c) / R (N blades of airfoil/bucket chord c m): 1) Darrieus Lift-Type H-Rotors (sigma = 0.15–0.40) fly symmetrical NACA 0018 blades at supersonic-to-wind Tip-Speed Ratios lambda = (omega * R) / V = (2 * PI() * R * (RPM / 60)) / V of 3.0–4.5 to reach C_p = 0.35–0.40 (near-HAWT efficiency, but near-zero starting torque at lambda < 1), whereas 2) Savonius Drag-Type S-Rotors (sigma ~= 1.8–2.2) self-start effortlessly with high torque at lambda ~= 0.8–1.0 at the cost of low peak C_p ~= 0.15–0.18. Standard sea-level air (rho = 1.225 kg/m³) yields Shaft Power P = (0.5 * 1.225 * (2 * R * H) * V^3 * C_p) / 1,000 (kW) and Rotor Shaft Torque tau = (P * 1,000) / (2 * PI() * (RPM / 60))** (N·m).

Verify on a 3-Blade Straight-Bladed Giromill / H-Darrieus VAWT—Rotor_Radius R = 3.20 m (B2), Blade_Span H = 8.50 m (B3 -> A = 54.4 m²), Blade_Count N = 3 (B4), Airfoil_Chord c = 0.36 m (B5), Wind_Speed V = 11.5 m/s (B6), Rotor_Speed = 125 RPM (B7), and Power_Coefficient C_p = 0.36 (B8): Solidity sigma equals 0.3375 (E2), Tip-Speed Ratio lambda equals 3.64 (E3), Shaft Power reaches 18.24 kW (E4), and Direct-Drive Generator Torque equals 1,393.7 N·m (E5).

VAWT Aerodynamic KPI (Sea-Level Air 1.225 kg/m³: Darrieus Lift vs Savonius Drag)FormulaVerified Output
Rotor Chord Solidity sigma (N*c/R)(Blade_Count_N * Chord_c_m) / Radius_R_m0.3375 Darrieus (2.0000 Savonius)
Tip-Speed Ratio lambda (TSR)(2 * PI() * Radius_m * (RPM / 60)) / Wind_m_s3.64 lift-driven (0.95 drag-limited)
Aerodynamic Shaft Power (kW)(0.5 * 1.225 * (2*R*H) * V^3 * Cp) / 100018.24 kW (0.55 kW compact Savonius)
Direct-Drive Rotor Torque (N·m)(Shaft_Power_kW * 1000) / (2 * PI() * RPM / 60)1,393.7 N·m (76.7 N·m Savonius)

VAWT Rectangular Swept-Area Power, Chord Solidity & Direct-Drive Torque Formula

Validate Radius R in [0.2, 60] m, Span H in [0.3, 120] m, integer Blades N in [2, 6], Chord c > 0.03 m, Wind_Speed V in [2, 40] m/s, RPM > 1, and physical Betz limit 0.05 <= C_p <= 0.5926.

=LET(rr_m, B2, hb_m, B3, nb_c, B4, ch_m, B5, vw_s, B6, nr_p, B7, cp_f, B8, pk_w, (0.5 * 1.225 * (2 * rr_m * hb_m) * (vw_s ^ 3) * cp_f) / 1000, IF(OR(rr_m < 0.2, rr_m > 60, hb_m < 0.3, hb_m > 120, nb_c < 2, nb_c > 6, ch_m <= 0.03, vw_s < 2, vw_s > 40, nr_p <= 1, cp_f < 0.05, cp_f > 0.5926), "Invalid VAWT Input", ROUND((pk_w * 1000) / (2 * PI() * (nr_p / 60)), 1)))

2-Scoop Savonius Drag Rotor (R = 1.2 m, H = 3 m, c = 1.2 m, Cp = 0.17) Comparison Check

Switch to a self-starting 2-bucket Savonius telecom-tower charger (B2 = 1.2, B3 = 3, B4 = 2, B5 = 1.2, B6 = 9, B7 = 68, B8 = 0.17): Solidity E2 jumps to 2.0000, Tip-Speed Ratio E3 stays sub-unity (0.95), Power E4 equals 0.55 kW, and Torque E5 equals 76.7 N·m.

=IF(ISTEXT(E5), E5, ROUND((0.5 * 1.225 * (2 * B2 * B3) * (B6 ^ 3) * B8) / 1000, 2))

Try the example

Use the original values or change them to test your understanding.

Further reading