Geotechnical Core Logging & Rock Mass Characterization, ASTM D6032 Deere RQD & Priest-Hudson
Deere Rock Quality Designation (RQD) & Joint Frequency
Calculate Total Core Recovery TCR (%), ASTM D6032 Measured Deere RQD (%), Priest & Hudson Theoretical RQD* (%) from Scanline Frequency lambda, and Palmstrom Volumetric Joint Count Jv.
92% Total Core Recovery does NOT mean good rock—fifteen 90 mm rubble sticks score 90%+ TCR yet ZERO percent Deere RQD
Don U. Deere (1964, ASTM D6032) revolutionized diamond core logging (NX / NQ >= 47.6 mm core diameter) by showing **Total Core Recovery TCR% = (Lrecovered / Lrun) * 100% masks closely jointed rock. Instead, Rock Quality Designation RQD% = (SUM(Lsound >= 100 mm) / Lrun) * 100% sums ONLY intact, hard core pieces >= 100 mm (4 in) measured along the centerline between natural geological joints (ignoring fresh mechanical drill/hammer breaks and dividing strictly by Total Drill Run Length Lrun, NEVER by recovered length Lrecovered). When core is unavailable (exposed tunnel faces or quarry benches), Priest & Hudson (1976) proved negative-exponential joint spacing with Linear Discontinuity Frequency lambda (joints/m) yields RQD* = 100 * EXP(-0.1 * lambda) * (0.1 * lambda + 1), while Palmström (1982) relates RQD to 3D Volumetric Joint Count J_v = (115 - RQD) / 3.3** (joints/m³).
Verify on a 1,500 mm (1.50 m) NQ3 Triple-Tube Core Run—Drill_Run_Advance Lrun = 1,500 mm (B2), Total_Recovered_Core Lrec = 1,380 mm (B3), Sum_of_Sound_Sticks_>=100mm = 1,095 mm (B4), and Outcrop_Scanline_Frequency lambda = 8.5 joints/m (B5): TCR equals 92.0% (E2), Measured ASTM D6032 RQD equals 73.0% (Fair-to-Good, E3—vs 79.3% if erroneously divided by 1,380 mm), Priest-Hudson Scanline RQD* equals 79.1% (E4), and Palmström J_v equals 12.73 joints/m³ (E5).
| ASTM D6032 Core Logging KPI (1,500 mm NQ3 Run: Moderately Jointed vs Fault Breccia) | Formula | Verified Output |
|---|---|---|
| Total Core Recovery TCR (%) | (Total_Recovered_mm / Total_Core_Run_mm) * 100 | 92.0% (76.0% in fault zone) |
| Measured Deere RQD (%) | (Sound_Sticks_100mm / Total_Core_Run_mm) * 100 | 73.0% Fair/Good (22.0% Very Poor) |
| Priest-Hudson Scanline RQD* (%) | 100 * EXP(-0.1 * lambda_m) * (0.1 * lambda_m + 1) | 79.1% @ 8.5/m (30.8% @ 24/m) |
| Palmström Volumetric Joints Jv (/m³) | (115 - Measured_RQD_Pct) / 3.3 | 12.73 joints/m³ (28.18 sugar-cube) |
ASTM D6032 Deere RQD, Priest-Hudson Poisson Spacing & Palmström Jv Formula
Validate Core_Run Lrun in [300, 6,000] mm, 0 <= Sound_100mm <= Recovered <= Core_Run, and Scanline_Frequency lambda in [0.1, 60] joints/m.
=LET(lr_n, B2, lt_r, B3, ls_d, B4, lm_j, B5, rq_m, (ls_d / lr_n) * 100, IF(OR(lr_n < 300, lr_n > 6000, lt_r < 0, lt_r > lr_n, ls_d < 0, ls_d > lt_r, lm_j < 0.1, lm_j > 60), "Invalid RQD Input", ROUND((115 - rq_m) / 3.3, 2)))Shattered Fault-Zone Rubble (L_rec = 1,140 mm, Sound >= 100mm = 330 mm, lambda = 24/m) Check
Core through a tectonic shear zone (B3 = 1,140 mm, B4 = 330 mm, B5 = 24 joints/m): TCR E2 still looks respectable at 76.0%, YET Deere RQD E3 collapses to 22.0% (Very Poor Rock, < 25%), Priest-Hudson RQD* E4 drops to 30.8%, and Volumetric Joint Count J_v E5 surges to 28.18 joints/m³.
=IF(ISTEXT(E5), E5, ROUND(100 * EXP(-0.1 * B5) * (0.1 * B5 + 1), 1))Try the example
Use the original values or change them to test your understanding.