Arte SheetsLearn. Try. Understand.

Statistical & Clinical Analysis

Forrester Hemodynamic Subsets: Cardiac Index and Wedge Pressure

Explore the historical four-subset classification using cardiac output, body surface area, and pulmonary capillary wedge pressure, without turning the result into an automatic diagnosis.

A historical hemodynamic classification

Forrester and colleagues studied clinical and invasive hemodynamic patterns after acute myocardial infarction. In the 1977 report, depressed cardiac index was 2.2 L/min/m² or less and elevated pulmonary capillary pressure was greater than 18 mmHg. The four subsets combine those two measurements; the original cohort results do not predict an individual patient’s outcome.

The later Nohria–Stevenson warm/cold and wet/dry profiles use clinical signs of perfusion and congestion at the bedside. They are related concepts but are not identical to a classification based only on catheter measurements. Clinical findings and measured pressures may disagree.

A subset is not, by itself, a diagnosis of cardiogenic shock or a prescription for fluids, drugs, or mechanical support. Contemporary shock assessment combines clinical findings, signs of tissue hypoperfusion, biochemical and imaging results, and hemodynamics over time.

Cardiac index (L/min/m²)Wedge pressure (mmHg)Historical pattern
> 2.2≤ 18I
> 2.2> 18II
≤ 2.2≤ 18III
≤ 2.2> 18IV

Illustrate the two-threshold comparison

Enter cardiac output in L/min in B2, body surface area in m² in B3, and pulmonary capillary wedge pressure in mmHg in B4. B2 is cardiac output, not an already indexed cardiac index: the formula divides B2 by B3. It compares the unrounded ratio with 2.2, then compares the wedge pressure with 18.

This is an educational spreadsheet example, not a validated medical device or a substitute for clinical assessment. Missing or nonnumeric inputs return a prompt; this example also requires positive cardiac output and body surface area and a nonnegative pressure.

=IF(COUNT(B2:B4)<>3,"Enter all three numeric inputs",IF(OR(B2<=0,B3<=0,B4<0),"Check input values",IF(B2/B3<=2.2,IF(B4>18,"Forrester pattern IV","Forrester pattern III"),IF(B4>18,"Forrester pattern II","Forrester pattern I"))))

Calculate cardiac index

The separately displayed cardiac index is cardiac output divided by body surface area and rounded to two decimal places. The pressure in B4 is not required for this arithmetic. Rounding the displayed index before the threshold comparison can change a boundary result.

=IF(COUNT(B2:B3)<>2,"Enter numeric cardiac output and surface area",IF(OR(B2<=0,B3<=0),"Check input values",ROUND(B2/B3,2)))

Try the example

Use the original values or change them to test your understanding.

Further reading