Arte SheetsLearn. Try. Understand.

Hydropower & Turbomachinery Engineering, Francis Reaction Turbine & Thoma Cavitation Law

Francis Turbine Specific Speed & Thoma Draft-Tube Formula

Calculate Metric Power Specific Speed Ns, Required Runner Suction Head NPSH_r (m), Maximum Safe Runner Elevation Above Tailwater Hs,max (m), and Cavitation Submergence Margin (m).

Set a high-specific-speed Francis hydro runner 1.2 m ABOVE tailwater at 1,000 m mountain altitude and draft-tube vacuum boils stainless runner blades into Swiss cheese

Francis Reaction Hydro Turbines recover 10%–25% of total net head H (m) inside a diverging Conical/Elbow Draft Tube that decelerates runner exit flow into static tailwater pressure—creating strong sub-atmospheric suction right at the runner throat. Classifying runner geometry by **Metric Power Specific Speed N_s = (N * SQRT(PMW * 1,000)) / H^1.25 (60–120 slow high-head Francis, 120–250 medium Francis, 250–400 fast low-head Francis; > 400 Kaplan axial), Dieter Thoma’s (1924) Cavitation Law defines Critical Cavitation Coefficient sigma_c = NPSH_r / H. Subtracting Required Suction Head NPSH_r = sigma_c * H (m) and Water Vapor Head H_v (m) from Altitude Barometric Head Hatm (m) fixes Maximum Safe Runner Setting Elevation Above Tailwater Hs,max = Hatm - H_v - sigma_c * H (m—whenever Hs,max < 0, the powerhouse MUST be excavated below minimum tailwater level**).

Verify on a 42 MW, 85 m Head Medium-Speed Francis Unit (300 RPM) near Sea Level (Hatm = 10.10 m)—Net_Head H = 85.0 m (B2), Synchronous_Speed N = 300 RPM (B3), Shaft_Power P = 42.0 MW (B4), Barometric_Head Hatm = 10.10 m (B5), 20°C Vapor_Head H_v = 0.24 m (B6), Thoma_Sigma sigma_c = 0.088 (B7), and Installed_Runner_Setting H_s = +1.20 m above tailwater (B8): Metric Specific Speed N_s equals 238.2 (E2), NPSH_r equals 7.48 m (E3), Max Allowable Elevation Hs,max equals +2.38 m (E4), leaving +1.18 m positive anti-cavitation margin (E5).

Francis Turbine Thoma KPI (300 RPM, 42 MW, Hv=0.24 m, Installed Hs=+1.20 m)FormulaVerified Output
Metric Power Specific Speed Ns(RPM * SQRT(Power_MW * 1000)) / (Head_m ^ 1.25)238.2 medium Francis (486.6 axial/fast)
Required Suction Head NPSHr (m)Thoma_Crit_Sigma * Net_Head_H_m7.48 m (10.56 m @ sigma=0.22)
Max Runner Elevation Hs,max (m)Barometric_m - Vapor_Hv_m - (sigma * H_m)+2.38 m (-1.60 m MUST SUBMERGE)
Net Submergence Safety Margin (m)Max_Setting_Hs_max_m - Installed_Hs_m+1.18 m safe (-2.80 m SEVERE CAVITATION)

Thoma (1924) Hydro-Turbine Cavitation Sigma & Draft-Tube Submergence Formula

Validate Net_Head H in [5, 800] m, Runner_RPM in [50, 1,500], Power in [0.1, 1,000] MW, Barometric_Head Hatm in [6.5, 10.6] m, Vapor_Head H_v in [0.05, 1.5] m, Thoma sigma_c in [0.02, 1.50], and Installed H_s in [-30, 8] m.

=LET(hn_m, B2, nr_p, B3, pm_w, B4, ha_m, B5, hv_m, B6, sc_t, B7, hs_i, B8, hm_x, ha_m - hv_m - (sc_t * hn_m), IF(OR(hn_m < 5, hn_m > 800, nr_p < 50, nr_p > 1500, pm_w < 0.1, pm_w > 1000, ha_m < 6.5, ha_m > 10.6, hv_m < 0.05, hv_m > 1.5, sc_t < 0.02, sc_t > 1.5, hs_i < -30, hs_i > 8), "Invalid Francis Input", ROUND(hm_x - hs_i, 2)))

Low-Head High-Altitude Powerhouse (H = 48 m, H_atm = 9.2 m, sigma = 0.22) Cavitation Check

Re-apply the +1.20 m setting to a 48 m head, 800 m altitude site (B2 = 48, B5 = 9.2, B7 = 0.22): Specific Speed E2 jumps to 486.6, Hs,max E4 turns negative (-1.60 m—requiring deep underground powerhouse submergence at least 1.60 m below minimum tailwater), and Margin E5 plunges to -2.80 m, triggering violent draft-tube vortex-rope surge and cavitation erosion.

=IF(ISTEXT(E5), E5, ROUND(B5 - B6 - (B7 * B2), 2))

Try the example

Use the original values or change them to test your understanding.

Further reading