Health Physics, Medical Linac / NDT Vaults & Gamma Shielding
Photon Attenuation: Half-Value and Tenth-Value Layers
Explore exponential attenuation, half-value and tenth-value layers in an ideal monoenergetic narrow-beam example, with the limits of that model made clear.
The narrow-beam model
For a monoenergetic narrow photon beam through a homogeneous material, the uncollided transmitted fraction is I/I₀ = EXP(−μx), where μ is the linear attenuation coefficient in cm⁻¹ and x is thickness in cm. In this idealized model the half-value layer is LN(2)/μ and the tenth-value layer is LN(10)/μ. The attenuation coefficient depends on photon energy and material.
This model does not by itself determine dose behind a real shield. Scattered radiation, source geometry and spectrum, openings, material properties and the detector or dose quantity all matter. A buildup factor is specific to its source, geometry, material, energy and quantity; an arbitrary factor is not an exact dose calculation. Shield design requires qualified radiation-protection analysis and measurements.
| Hypothetical μ = 0.58 cm⁻¹ | Calculation | Result |
|---|---|---|
| Half-value layer | LN(2) / 0.58 | 1.195 cm |
| Tenth-value layer | LN(10) / 0.58 | 3.970 cm |
| Uncollided fraction at 6 cm | EXP(−0.58 × 6) | 0.030807 |
Calculate an idealized half-value layer
Enter a positive hypothetical linear attenuation coefficient in B2, in cm⁻¹. This numerical example does not identify a material or photon energy.
=IF(COUNT(B2)<>1,"Enter numeric attenuation coefficient",IF(B2<=0,"Check attenuation coefficient",ROUND(LN(2)/B2,3)))Calculate an idealized tenth-value layer
The value is a factor LN(10)/LN(2) times the narrow-beam half-value layer under the same assumptions.
=IF(COUNT(B2)<>1,"Enter numeric attenuation coefficient",IF(B2<=0,"Check attenuation coefficient",ROUND(LN(10)/B2,3)))Calculate an uncollided fraction
Enter a nonnegative material thickness in centimetres in B3. The fraction excludes scattered photons reaching a detector; it must not be treated as total broad-beam dose.
=IF(COUNT(B2:B3)<>2,"Enter numeric coefficient and thickness",IF(OR(B2<=0,B3<0),"Check coefficient and thickness",ROUND(EXP(-B2*B3),6)))Try the example
Use the original values or change them to test your understanding.