Arte SheetsLearn. Try. Understand.

Health Physics, Medical Linac / NDT Vaults & Gamma Shielding

Photon Attenuation: Half-Value and Tenth-Value Layers

Explore exponential attenuation, half-value and tenth-value layers in an ideal monoenergetic narrow-beam example, with the limits of that model made clear.

The narrow-beam model

For a monoenergetic narrow photon beam through a homogeneous material, the uncollided transmitted fraction is I/I₀ = EXP(−μx), where μ is the linear attenuation coefficient in cm⁻¹ and x is thickness in cm. In this idealized model the half-value layer is LN(2)/μ and the tenth-value layer is LN(10)/μ. The attenuation coefficient depends on photon energy and material.

This model does not by itself determine dose behind a real shield. Scattered radiation, source geometry and spectrum, openings, material properties and the detector or dose quantity all matter. A buildup factor is specific to its source, geometry, material, energy and quantity; an arbitrary factor is not an exact dose calculation. Shield design requires qualified radiation-protection analysis and measurements.

Hypothetical μ = 0.58 cm⁻¹CalculationResult
Half-value layerLN(2) / 0.581.195 cm
Tenth-value layerLN(10) / 0.583.970 cm
Uncollided fraction at 6 cmEXP(−0.58 × 6)0.030807

Calculate an idealized half-value layer

Enter a positive hypothetical linear attenuation coefficient in B2, in cm⁻¹. This numerical example does not identify a material or photon energy.

=IF(COUNT(B2)<>1,"Enter numeric attenuation coefficient",IF(B2<=0,"Check attenuation coefficient",ROUND(LN(2)/B2,3)))

Calculate an idealized tenth-value layer

The value is a factor LN(10)/LN(2) times the narrow-beam half-value layer under the same assumptions.

=IF(COUNT(B2)<>1,"Enter numeric attenuation coefficient",IF(B2<=0,"Check attenuation coefficient",ROUND(LN(10)/B2,3)))

Calculate an uncollided fraction

Enter a nonnegative material thickness in centimetres in B3. The fraction excludes scattered photons reaching a detector; it must not be treated as total broad-beam dose.

=IF(COUNT(B2:B3)<>2,"Enter numeric coefficient and thickness",IF(OR(B2<=0,B3<0),"Check coefficient and thickness",ROUND(EXP(-B2*B3),6)))

Try the example

Use the original values or change them to test your understanding.

Further reading