Calculate Maximum Safe Annealing Lehr Cooling Rate hmax (°C/min), Critical Strain-Point Cooling Time (min), Polariscope Optical Retardation (nm/cm), and Anneal Quality Class.
Switch a float-glass annealing lehr from 8 mm architectural glass to 19 mm heavy plate without slowing cooling 6x and the ribbon snaps cleanly in half on the cutting table
Whereas thermal tempering *intentionally* freezes high >69 MPa surface compression so glass cannot be cut, Float-Glass & Optical Annealing Lehrs must cool glass slowly through its ~550°C Annealing Point down past its ~440°C Strain Point (Annealing Span Delta_Tann ~= 110°C) so permanent residual stress sigmaperm stays low enough (<= 2.5 MPa commercial float, <= 1.0 MPa precision optical) for clean diamond-wheel scoring without spontaneous running cracks. By L. H. Adams & E. D. Williamson’s (1920) Thermo-Viscoelastic Annealing Law, cooling a slab of Thickness d (mm) and Thermal Diffusivity alpha (mm²/s) at constant rate h_c (°C/min) induces a parabolic temperature lag Delta_T = (h_c / 60) * d^2 / (8 * alpha) that locks in permanent room-temperature stress sigmaperm = (beta * d^2 * h_c) / (720 * alpha)—limiting **Maximum Safe Cooling Rate hmax = (720 * alpha * sigmaallow) / (beta * d^2) (°C/min, scaling inversely with d^2) and Polariscope Optical Retardation Ropt = sigmaallow * 26.0** (nm/cm for soda-lime Brewster constant 2.60 TPa⁻¹).
Verify on an 8.0 mm Commercial Float-Glass Ribbon—Plate_Thickness d = 8.0 mm (B2), Max_Allowable_Stress sigmaallow = 2.50 MPa (B3), Glass_Thermal_Diffusivity alpha = 0.52 mm²/s (B4), Thermoelastic_Constant beta = 0.82 MPa/K (B5), and Critical_Annealing_Range Delta_Tann = 110°C (B6): Max Safe Cooling Rate hmax equals 17.84 °C/min (E2), Critical Zone Transit Time equals 6.2 min (E3), Polariscope Retardation equals 65.0 nm/cm (E4), qualifying as "COMMERCIAL FLOAT ANNEALED" (E5).
| Adams-Williamson Annealing Lehr KPI (alpha=0.52 mm²/s, beta=0.82 MPa/K, Span=110°C) | Formula | Verified Output |
|---|---|---|
| Max Safe Lehr Cooling Rate (°C/min) | (720 * alpha_mm2_s * Allow_MPa) / (beta * d_mm^2) | 17.84 °C/min (1.26 °C/min @ 19 mm optical) |
| Critical Zone Cooling Time (min) | Annealing_Range_C / Max_Cooling_C_min | 6.2 min (87.0 min = 14x longer lehr dwell) |
| Polariscope Birefringence (nm/cm) | Allowable_Stress_MPa * 26.0 (Brewster Const) | 65.0 nm/cm float (26.0 nm/cm precision lens) |
| Optical Annealing Grade | <= 30 nm/cm Fine Optical Retardation Gate | COMMERCIAL FLOAT ANNEALED |
Adams & Williamson (1920) Inverse-Square Thickness Lehr Cooling Formula
Validate Thickness d in [1.0, 150.0] mm, Allowable_Stress sigmaallow in [0.1, 15.0] MPa, Diffusivity alpha in [0.2, 1.5] mm²/s, Thermoelastic beta in [0.3, 1.5] MPa/K, and Annealing_Span in [40, 200]°C right on E2 (checking ISTEXT(E2) on E3..E4 so E5 text stays decoupled).
=LET(dm_m, B2, sa_m, B3, al_d, B4, bt_m, B5, dt_c, B6, ro_n, sa_m * 26, IF(OR(dm_m < 1, dm_m > 150, sa_m < 0.1, sa_m > 15, al_d < 0.2, al_d > 1.5, bt_m < 0.3, bt_m > 1.5, dt_c < 40, dt_c > 200), "Invalid Lehr Input", IF(ro_n <= 30, "PRECISION OPTICAL (<=30 nm/cm)", "COMMERCIAL FLOAT ANNEALED")))19 mm Heavy Optical Window Blank (d = 19 mm, sigma = 1.0 MPa) 14x Slowdown Check
Anneal a 19.0 mm (3/4") optical window blank to B3 = 1.0 MPa (26.0 nm/cm birefringence in E4 -> "PRECISION OPTICAL (<=30 nm/cm)" in E5): because thickness d^2 jumps 5.64x AND stress target tightens 2.5x, Safe Cooling Rate E2 plunges 14.1x from 17.84 down to 1.26 °C/min, stretching critical lehr cooling E3 to 87.0 minutes.
=IF(ISTEXT(E2), E2, LET(hm_x, (720 * B4 * B3) / (B5 * (B2 ^ 2)), ROUND(B6 / hm_x, 1)))Try the example
Use the original values or change them to test your understanding.