Mass Timber & Structural Wood Design, NDS Hankinson Grain-Angle Bearing Formula
Hankinson Wood Grain-Angle Bearing Strength Formula
Calculate NDS Hankinson Inclined-to-Grain Bearing Strength F_theta (MPa), Retained Parallel Strength (%), Allowable Joint Bearing Load (kN), and Naive Linear Error (MPa).
Never linearly interpolate timber strength between 0° and 90°—wood crushes sideways like bundled drinking straws at 35°
Structural Douglas-Fir, Southern Pine, and Glulam timber is strongly orthotropic: cellulose tracheid fibers carry 3.5x–5x higher compression Parallel to Grain F_c (MPa, 0° end-grain column bearing) than Perpendicular to Grain Fc,perp (MPa, 90° sill-plate side crushing). When a heavy-timber roof truss rafter meets a tie-beam birdsmouth notch or split-ring bolt at Load-to-Grain Angle theta (0° <= theta <= 90°), naive linear interpolation (F_c - (F_c - Fc,perp) * (theta / 90)) dangerously overpredicts strength by +33% to +52%. Under the AWC National Design Specification (NDS) / Eurocode 5 Hankinson Equation, inclined bearing strength follows the harmonic trig surface **F_theta = (F_c * Fc,perp) / (F_c * SIN(theta)^2 + Fc,perp * COS(theta)^2), multiplying Contact Notch Area A_b (mm²) for Allowable Joint Bearing Load (F_theta * A_b) / 1,000** (kN).
Verify on a Douglas-Fir Glulam Truss Heel Notch—Parallel-to-Grain_Strength F_c = 13.50 MPa (B2), Perpendicular-to-Grain_Strength Fc,perp = 3.80 MPa (B3), Rafter_Chord_Angle theta = 35.0° (B4), and Birdsmouth_Bearing_Area A_b = 9,600 mm² (120 x 80 mm, B5): Hankinson Inclined Strength drops to 7.34 MPa (E2 = 54.35% of F_c in E3), Allowable Joint Load equals 70.44 kN (E4), whereas Naive Linear Interpolation falsely predicts 9.73 MPa (E5 = +32.6% unsafe overprediction).
| AWC NDS Hankinson Timber KPI (Fc=13.5 MPa, Fc_perp=3.8 MPa, theta=35°, Ab=9,600 mm²) | Formula | Verified Output |
|---|---|---|
| Hankinson Strength F_theta (MPa) | (Fc * Fcp) / (Fc*SIN(rad)^2 + Fcp*COS(rad)^2) | 7.34 MPa (4.63 MPa @ steep 60° pitch) |
| Retained Parallel Strength (%) | (Hankinson_F_theta / Parallel_Fc) * 100 | 54.35% (34.31% @ steep 60° pitch) |
| Allowable Notch Bearing Load (kN) | (Hankinson_F_theta_MPa * Area_mm2) / 1000 | 70.44 kN (44.47 kN @ steep 60° pitch) |
| Naive Linear Interpolation (MPa) | Fc - (Fc - Fcp) * (Angle_deg / 90) (UNSAFE) | 9.73 MPa (+32.6% unsafe overprediction) |
AWC NDS Hankinson Orthotropic Grain-Angle Bearing Formula
Validate Perp_Strength Fc,perp > 0.5 MPa, Parallel F_c > Fc,perp, Grain_Angle theta in [0°, 90°], and Bearing_Area A_b > 100 mm². In a shared structural-calculation workbook, a timber detailer can @mention the engineer of record in a whole-cell comment on E2 to verify whether wet-service factor C_M has already been applied to B2:B3.
=LET(fc_p, B2, fp_p, B3, ag_d, B4, ab_m, B5, IF(OR(fp_p <= 0.5, fc_p <= fp_p, ag_d < 0, ag_d > 90, ab_m <= 100), "Invalid Timber Input", ROUND(fc_p - (fc_p - fp_p) * (ag_d / 90), 2)))Steep 60° A-Frame Strut Side-Grain Crushing Check (Set Grain Angle B4 = 60°)
Steepen the timber strut angle to theta B4 = 60°: Hankinson Strength E2 plunges to 4.63 MPa (34.31% retained in E3, Joint Capacity = 44.47 kN in E4)—nearly 2.40 MPa below Naive Linear 7.03 MPa (E5), requiring a steel shoe washer or widened bearing seat.
=IF(ISTEXT(E5), E5, LET(rd_a, B4 * (PI() / 180), ROUND((B2 * B3) / (B2 * (SIN(rd_a) ^ 2) + B3 * (COS(rd_a) ^ 2)), 2)))Try the example
Use the original values or change them to test your understanding.