Arte SheetsLearn. Try. Understand.

Precision Machine-Tool Tables & Observatory Azimuth Bearings, Hydrostatic Thrust Pad

Hydrostatic Circular Step Thrust-Pad Load & h³ Flow Formula

Calculate Exact Radial-Log Pad Load Capacity W (kN), Viscous Sill Leakage Flow Q (L/min), Hydraulic Sill Pumping Power (W and kW), and Cubic Film-Gap Sensitivity.

Doubling a hydrostatic bearing’s oil-film gap from 55 to 110 um leaves load lift unchanged—while Poiseuille’s h^3 law multiplies oil leakage and pump heating 8-FOLD

Unlike *hydrodynamic* tilting-pad bearings that need sliding velocity to build an oil wedge, Externally Pressurized Hydrostatic Circular Step-Recess Thrust Pads (Outer Sill Radius R_o mm, Central Pocket Radius R_i mm, Recess Supply Pocket Pressure P_r MPa, Oil Dynamic Viscosity mu Pa·s) float 200-ton vertical boring-mill tables and 30-m optical telescope mounts at zero RPM with zero stick-slip friction. Integrating radial Poiseuille laminar flow p(r) = P_r * ln(R_o / r) / ln(R_o / R_i) across the annular land yields **Exact Vertical Lift Load W = ((pi * P_r * (R_o^2 - R_i^2)) / (2 * ln(R_o / R_i))) / 1,000 (kN), Sill Oil Flow Q = ((pi * (P_r * 10⁶) * ((h * 10⁻⁶)^3)) / (6 * mu * ln(R_o / R_i))) * 60,000 (L/min at Film Clearance h um), and Pocket Hydraulic Pumping Power Ppump = (P_r * 1,000 * Q) / 60 (W, / 1,000 kW)—scaling strictly with h^3**.

Verify on a Heavy Vertical Turning Lathe Hydrostatic Table Pad (ISO VG 46 Oil at 40°C)—Outer_Pad_Radius R_o = 160 mm (B2), Recess_Pocket_Radius R_i = 85.0 mm (B3), Pocket_Pressure P_r = 4.80 MPa (48 bar, B4), Dynamic_Viscosity mu = 0.046 Pa·s (46 mPa·s, B5), and Film_Clearance h = 55.0 um (B6): Vertical Pad Load Capacity equals 219.03 kN (22.3 metric tons per pad. E2), Sill Oil Flow equals 0.862 L/min (E3), consuming just 69.0 W (0.069 kW in E5) of hydraulic pocket power.

Hydrostatic Circular Step Pad KPI (Ro=160 mm, Ri=85 mm, Pr=4.8 MPa, mu=0.046 Pa·s)FormulaVerified Output
Pad Lift Load Capacity W (kN)((PI() * Pr * (Ro^2 - Ri^2)) / (2 * LN(Ro/Ri))) / 1000219.03 kN (independent of gap h @ fixed Pr)
Viscous Sill Flow Q (L/min)((PI * Pr_Pa * h_m^3) / (6 * mu * LN(Ro/Ri))) * 600000.862 L/min @ 55 um (6.898 L/min @ 110 um)
Pocket Pumping Power (W)(Pocket_Pr_MPa * 1000 * Flow_L_min) / 6069.0 W cool (551.9 W = 8.0x thermal load)
Pocket Pumping Power (kW)Pocket_Pumping_Power_W / 10000.069 kW (0.552 kW chiller load)

Radial Poiseuille Hydrostatic Step-Pad Load & Cubic h³ Flow Formula

Validate Inner_Radius R_i >= 5 mm, Outer_Radius R_o in (1.15 * R_i, 2,500] mm, Pocket_Pressure P_r in [0.2, 50.0] MPa, Oil_Viscosity mu in [0.002, 1.000] Pa·s, and Film_Gap h in [5, 500] um.

=LET(ro_m, B2, ri_m, B3, pr_m, B4, mu_p, B5, hf_u, B6, ql_m, ((PI() * (pr_m * 1000000) * ((hf_u * 0.000001) ^ 3)) / (6 * mu_p * LN(ro_m / ri_m))) * 60000, pw_w, (pr_m * 1000 * ql_m) / 60, IF(OR(ri_m < 5, ro_m <= 1.15 * ri_m, ro_m > 2500, pr_m < 0.2, pr_m > 50, mu_p < 0.002, mu_p > 1, hf_u < 5, hf_u > 500), "Invalid Pad Input", ROUND(pw_w / 1000, 3)))

Doubled Film Clearance (h = 110 um) 8x Oil-Chiller Thermal-Distortion Check

Open capillary/constant-pressure restrictor clearance to B6 = 110.0 um (2.0x baseline) at fixed 4.80 MPa pocket pressure: Pad Load E2 stays 219.03 kN, YET Sill Leakage E3 jumps 2^3 = 8.00x to 6.898 L/min and Pumping Heat E4 jumps 8.00x to 551.9 W (0.552 kW per pad in E5)—forcing oil chillers onto precision CNC beds so warm return oil never thermally bows the machine table.

=IF(ISTEXT(E5), E5, ROUND(((PI() * (B4 * 1000000) * ((B6 * 0.000001) ^ 3)) / (6 * B5 * LN(B2 / B3))) * 60000, 3))

Try the example

Use the original values or change them to test your understanding.

Further reading