Geotechnical Engineering, Landslide Hazard & Hillslope Hydrology
Infinite-Slope Model: Illustrative Dry and Seepage Cases
Explore a simplified infinite-slope equation using hypothetical dry and surface-parallel seepage cases, with assumptions and limits made explicit.
A simplified, idealised model
The infinite-slope approximation considers a long, uniform slope with a planar failure surface parallel to the ground. A simplified effective-stress expression separates a cohesion term from a friction term: F = c′/[γz sin β cos β] + [(γ − mγw)/γ] tan φ′/tan β. Here β is slope angle, z is vertical depth to the potential slip plane, γ is the assumed average total unit weight of the soil column, c′ and φ′ are effective-strength parameters, and γw is taken as 9.81 kN/m³.
The dimensionless m is the height of the assumed water table above the slip plane divided by the vertical depth z; m = 0 places it at the plane and m = 1 at the surface. This teaching expression assumes an idealised slope-parallel water table and parallel seepage, and neglects suction in soil above the water table. It does not model transient rainfall, changing hydraulic conditions, complex layers or actual failure mechanisms.
Use an appropriate total unit weight for each assumed case: the average overburden weight can change as water content changes. The model results below compare two hypothetical parameter sets, not the evolution of a measured slope during a storm.
| Hypothetical case | Assumed γ (kN/m³) | Water-table ratio m | Cohesion term | Friction term | Modelled factor |
|---|---|---|---|---|---|
| Dry, no pore pressure in this model | 18.00 | 0 | 0.478 | 1.403 | 1.882 |
| Saturated, parallel seepage to surface | 19.62 | 1 | 0.439 | 0.702 | 1.141 |
Calculate the terms
Both examples use β = 24°, z = 2.50 m, c′ = 8 kPa and φ′ = 32°. For the specific saturated unit weight 19.62 kN/m³ and γw = 9.81 kN/m³, the friction coefficient is one half of the dry expression; this is an arithmetic property of these chosen numbers, not a universal effect of rainfall.
The worksheet stores the unrounded model value in E4 and rounds only the displayed values. The numeric and range checks are limits for the example, not verification of a geotechnical model or soil properties.
=IF(COUNT(B2:B7)<>6,"Enter all numeric inputs",IF(OR(B2<=0,B2>75,B3<=0,B4<13,B5<0,B6<0,B6>50,B7<0,B7>1),"Check example inputs",B5/(B4*B3*SIN(RADIANS(B2))*COS(RADIANS(B2)))+((B4-B7*9.81)/B4)*(TAN(RADIANS(B6))/TAN(RADIANS(B2)))))What this calculation cannot decide
Do not use the output to label a real slope stable or failed, or to decide protective works. A qualified geotechnical assessment considers the ground, groundwater, loading, material uncertainty, possible failure surfaces and the applicable design criteria. A real storm can change pore pressure and soil weight in ways this steady idealisation does not represent.
The USGS describes more detailed models for transient rainfall infiltration; FHWA and USACE also describe the assumptions and limits of infinite-slope and other stability methods.
Try the example
Use the original values or change them to test your understanding.