Arte SheetsLearn. Try. Understand.

Bulk Solids Mechanics, Eurocode EN 1991-4 Grain/Cement Silo Design & Janssen Theory

Janssen Silo Wall Friction & Pressure Saturation Formula

Calculate Janssen Characteristic Screening Depth z0 (m), Saturated Vertical Floor Pressure Pv(z) (kPa), Lateral Silo Wall Hoop Pressure Ph(z) (kPa), and Naive Hydrostatic Fluid Overprediction (kPa).

Why an hourglass ticks at constant rate—and why grain silo floor pressure saturates instead of growing likerho*g*z

Designing a tall grain, polymer-pellet, or cement silo as a hydrostatic liquid tank (P = rho * g * z) wildly overdesigns the bottom hopper while missing wall-buckling vertical friction drag. H. A. Janssen (1895) proved that horizontal active/passive earth-pressure ratio K = P_h / P_v pushes granular solids outward against the cylinder wall, mobilizing upward Wall Shear Friction tau_w = mu_w * P_h = mu_w * K * P_v across Hydraulic Radius R_h = Area / Perimeter = D / 4 (for a circular bin of diameter D). Integrating the differential slice balance dP_v/dz + (P_v / z_0) = rho * g defines Characteristic Janssen Screening Depth z_0 = R_h / (mu_w * K) (m) and Exponential Saturation P_v(z) = (rho * g * z_0 / 1,000) * (1 - EXP(-z / z_0)) kPa, with Lateral Hoop Pressure P_h(z) = K * P_v(z) kPa—transferring most of the column weight into vertical compression down the steel silo shell.

Verify on a 6.0 m Diameter Corrugated-Steel Wheat Silo Filled to 20.0 m—Silo_Diameter D = 6.00 m (R_h = 1.50 m, B2), Grain_Fill_Depth z = 20.00 m (B3), Bulk_Density rho_b = 780.0 kg/m³ (B4), Grain-on-Wall_Friction mu_w = 0.40 (B5), and Janssen_Lateral_Ratio K = 0.48 (B6): Characteristic Depth z_0 equals 7.81 m (E2), Vertical Bottom Pressure P_v saturates at 55.14 kPa (E3, nearly 3x below naive 152.98 kPa hydrostatic fluid pressure in E5), and Lateral Wall Hoop Pressure P_h equals 26.47 kPa (E4).

Eurocode EN 1991-4 Silo KPI (D=6.0 m, z=20 m, rho=780 kg/m³, mu_w=0.40, K=0.48)FormulaVerified Output
Characteristic Screening Depth z0(D_m / 4) / (Wall_Friction_mu * K)7.81 m (12.50 m @ smooth steel 0.25)
Vertical Silo Pressure Pv(z) (kPa)(rho*g*z0/1000) * (1 - EXP(-z / z0))55.14 kPa (76.31 kPa @ smooth 0.25)
Lateral Wall Hoop Pressure Ph (kPa)K_Ratio * Pv_z_kPa26.47 kPa (36.63 kPa @ smooth 0.25)
Naive Hydrostatic Fluid rho*g*z(rho_kg_m3 * 9.80665 * z_m) / 1000152.98 kPa (2.77x overprediction)

Janssen Differential-Slice Exponential Silo Pressure Formula

Validate Silo_Diameter D > 0 m, Depth z > 0 m, Bulk_Density > 0 kg/m³, Wall_Friction mu_w in (0.05, 1.0], and Lateral_Ratio K in (0.15, 1.0]. Note EN 1991-4 tests BOTH upper-bound mu_w (maximizing vertical shell buckling drag) AND lower-bound smooth mu_w (maximizing hopper & hoop burst pressure).

=LET(dm_s, B2, dp_z, B3, rb_k, B4, mw_f, B5, kr_j, B6, IF(OR(dm_s <= 0, dp_z <= 0, rb_k <= 0, mw_f <= 0.05, mw_f > 1, kr_j <= 0.15, kr_j > 1), "Invalid Silo Input", ROUND((rb_k * 9.80665 * dp_z) / 1000, 2)))

Polished Smooth Stainless Wall Lower-Friction Burst Check (Set Wall Friction mu_w = 0.25)

Polish the bin liner so Wall Friction mu_w B5 drops from 0.40 down to 0.25: less weight hangs on the walls, lengthening Characteristic Depth E2 to 12.50 m and driving Floor Pressure E3 up +38.4% to 76.31 kPa and Lateral Hoop Burst Pressure E4 up to 36.63 kPa.

=IF(ISTEXT(E5), E5, LET(zc_m, (B2 / 4) / (B5 * B6), pv_k, ((B4 * 9.80665 * zc_m) / 1000) * (1 - EXP(-B3 / zc_m)), ROUND(B6 * pv_k, 2)))

Try the example