Wind-Tunnel Turbulence & Experimental Aerodynamics, L.V. King (1914) CTA Anemometry
King’s Law CTA Hot-Wire Anemometer Velocity Formula
Calculate Active Wire Overheat Difference (K), Bearman-Corrected Squared Bridge Voltage E²corr (V²), True Compensated Flow Velocity (m/s), and Uncorrected Raw Velocity (m/s).
Closed-return wind-tunnel air warming +27 K during a run tricks an un-compensated 520 K CTA hot-wire probe into reading 24.6 m/s when true airspeed is 36.6 m/s (-33% error)
Louis Vessot King (1914) established the boundary-layer heat-transfer law for Constant-Temperature Hot-Wire Anemometers (CTA), where a 100-kHz servo Wheatstone bridge holds a 5-um tungsten filament at constant Overheat Temperature T_w (K): at Calibration Air Temperature T_0 (K), **Squared Bridge Voltage obeys E^2 = A + B * (U^n) (with King’s theoretical exponent n = 0.50, or calibrated n ~= 0.45 by Collis & Williams). Yet if test-section air warms or cools to T_f (K), convective heat loss scales with (T_w - T_f)—so before inverting King’s Law, Bearman’s Temperature-Drift Correction Ecorr^2 = Emeas^2 * ((T_w - T_0) / (T_w - T_f)) (V²) MUST be applied to recover True Fluid Velocity Utrue = ((Ecorr^2 - A) / B)^(1 / n)** (m/s).
Verify on a 5-um Tungsten Boundary-Layer Probe at Calibration Temperature (T_f = T_0 = 295 K)—Measured_Bridge_Voltage E = 2.36 V (B2), King_Zero-Flow_Intercept A = 1.68 V² (B3), King_Slope B = 0.92 V²/(m/s)^n (B4), Calibrated_Exponent n = 0.45 (B5), Sensor_Wire_Temp T_w = 520 K (B6), Calibration_Fluid_Temp T_0 = 295 K (B7), and Actual_Tunnel_Temp T_f = 295 K (B8): Active Overheat T_w - T_f equals 225.0 K (E2), Temperature-Corrected Ecorr^2 equals 5.570 V² (E3), and both True Velocity (E4) and Raw Uncorrected Velocity (E5) agree at 24.62 m/s.
| King’s Law (1914) CTA Anemometer KPI (E=2.36 V, A=1.68 V², B=0.92, n=0.45, Tw=520 K) | Formula | Verified Output |
|---|---|---|
| Active Wire Overheat Tw - Tf (K) | Wire_Temp_Tw_K - Actual_Fluid_Tf_K | 225.0 K @ 295 K (198.0 K @ 322 K tunnel) |
| Temp-Corrected E²corr (V²) | (Bridge_E_V ^ 2) * ((Tw - T0) / (Tw - Tf)) | 5.570 V² (6.329 V² drift-compensated) |
| True Compensated Velocity (m/s) | ((Corrected_E2 - King_A) / King_B) ^ (1 / n) | 24.62 m/s (36.60 m/s TRUE airspeed) |
| Uncorrected Raw Velocity (m/s) | (((Bridge_E_V^2) - King_A) / King_B) ^ (1 / n) | 24.62 m/s (24.62 m/s = -32.7% ERROR) |
L.V. King (1914) & Collis-Williams CTA Temperature-Compensated Velocity Formula
Validate Intercept A >= 0.1 V², Slope B > 0, Exponent n in [0.30, 0.65], Wire_Temp T_w in [350, 900] K, Cal/Actual Fluid Temps in [240, T_w - 40] K, and E^2 > A & Ecorr^2 > A.
=LET(em_v, B2, az_v, B3, bs_k, B4, nx_k, B5, tw_k, B6, tz_k, B7, tf_k, B8, ec_s, (em_v ^ 2) * ((tw_k - tz_k) / (tw_k - tf_k)), IF(OR(az_v < 0.1, bs_k <= 0, nx_k < 0.3, nx_k > 0.65, tw_k < 350, tw_k > 900, tz_k < 240, tz_k > tw_k - 40, tf_k < 240, tf_k > tw_k - 40, (em_v ^ 2) <= az_v, ec_s <= az_v), "Invalid HotWire Input", ROUND((((em_v ^ 2) - az_v) / bs_k) ^ (1 / nx_k), 2)))Un-Chilled Wind-Tunnel Heating (T_f = 322 K = 48.9°C at Same 2.36 V) 33%-Error Check
Let fan friction warm recirculating wind-tunnel air to B8 = 322.0 K (Overheat E2 shrinks 12% to 198.0 K) while bridge voltage still reads 2.36 V: Because 1 / n = 2.222 amplifies small voltage-squared shifts nonlinearly, Uncorrected Raw Velocity E5 stays stuck at 24.62 m/s while True Airspeed E4 is actually 36.60 m/s (Ecorr^2 = 6.329 V² in E3)—proving an RTD temperature probe MUST always accompany every CTA hot-wire channel.
=IF(ISTEXT(E5), E5, LET(ec_s, (B2 ^ 2) * ((B6 - B7) / (B6 - B8)), ROUND(((ec_s - B3) / B4) ^ (1 / B5), 2)))Try the example
Use the original values or change them to test your understanding.