Industrial Electric Drives & Rotating Machinery, Kloss Asynchronous Motor Torque-Slip Law
Kloss Induction Motor Torque-Slip & Breakdown Formula
Calculate Synchronous Rotating-Field Speed Ns (RPM), Rotor Slip s (%), Kloss Electromagnetic Shaft Torque T(s) (N·m), and Direct-On-Line (s = 1) Locked-Rotor Starting Torque (N·m).
Push a squirrel-cage induction motor past its 14% breakdown slip knee and rising slip REDUCES torque—snapping the shaft straight to locked-rotor stall
In a Three-Phase Squirrel-Cage Asynchronous Induction Motor (Grid Frequency f Hz, Stator Pole Count P -> **Synchronous Rotating Field Speed N_s = (120 * f) / P RPM), rotor bars must turn slightly slower (Shaft Speed N RPM) at Fractional Slip s = (N_s - N) / N_s to cut stator flux lines and induce rotor current. Neglecting minor stator resistance, Max Kloss’s (1916) Canonical Torque-Slip Equation** expresses electromagnetic torque at *any* slip s purely from Pull-Out / Breakdown Torque Tmax (N·m) and Breakdown Slip s_m = R2,ref / Xeq: **T(s) = (2 * Tmax) / ((s / s_m) + (s_m / s))** (N·m). For small operating slips (s << s_m), T ~= 2 * Tmax * (s / s_m) rises linearly like a stiff DC shunt motor; at s = s_m, torque peaks at Tmax; beyond s > s_m (the unstable front slope), rotor leakage reactance chokes power factor so T(s) falls hyperbolically down to **Locked-Rotor Starting Torque (s = 1): Tstart = (2 * Tmax) / ((1 / s_m) + s_m)**.
Verify on a 4-Pole, 60 Hz NEMA Design B Industrial Pump Motor—Grid_Frequency f = 60.0 Hz (B2), Stator_Poles P = 4 (B3 -> N_s = 1,800 RPM in E2), Operating_Speed N = 1,755 RPM (B4), Breakdown_Slip s_m = 0.14 (14%, B5), and Pull-Out_Torque Tmax = 310.0 N·m (B6): Operating Slip equals 2.50% (E3), Operating Shaft Torque equals 107.3 N·m (19.8 kW. E4), and Direct-On-Line (s = 1) Locked-Rotor Starting Torque equals 85.1 N·m (E5, showing why NEMA deep-bar rotors use skin effect at 60 Hz rotor frequency to boost starting R_2).
| Kloss Induction Motor KPI (60 Hz, 4-Pole -> Ns=1,800 RPM, sm=0.14, Tmax=310 N·m) | Formula | Verified Output |
|---|---|---|
| Synchronous Field Speed Ns (RPM) | (120 * Grid_Freq_Hz) / Stator_Poles_P | 1,800 RPM |
| Operating Rotor Slip s (%) | ((Ns_RPM - Shaft_N_RPM) / Ns_RPM) * 100 | 2.50% rated (17.00% > 14% UNSTABLE) |
| Kloss Shaft Torque T(s) (N·m) | (2 * Tmax_Nm) / ((s / sm) + (sm / s)) | 107.3 N·m (304.2 N·m collapsing past knee) |
| Locked-Rotor Torque @ s = 1 (N·m) | (2 * Tmax_Nm) / ((1 / sm) + sm) | 85.1 N·m (classical constant-R2 floor) |
Max Kloss (1916) Dimensionless Symmetrical Slip-Ratio Torque Formula
Validate Frequency f in [10, 400] Hz, even integer Poles P in [2, 24], motoring speed 0 <= N < N_s, Breakdown_Slip s_m in [0.03, 0.80], and Pull-Out Torque Tmax > 1 N·m.
=LET(fg_h, B2, pc_n, B3, nr_p, B4, sm_b, B5, tm_n, B6, ns_r, (120 * fg_h) / pc_n, IF(OR(fg_h < 10, fg_h > 400, pc_n < 2, pc_n > 24, MOD(pc_n, 2) <> 0, nr_p < 0, nr_p >= ns_r, sm_b < 0.03, sm_b > 0.8, tm_n <= 1), "Invalid Kloss Input", ROUND((2 * tm_n) / ((1 / sm_b) + sm_b), 1)))Mechanical Jam / Voltage Sag Past Breakdown Knee (N = 1,494 RPM -> s = 17% > 14%) Stall Check
Drag shaft speed down to B4 = 1,494 RPM (Slip s = 17.00% in E3, past s_m = 14%): Torque E4 has ALREADY peaked at 310 N·m (1,548 RPM) and is now falling (304.2 N·m)—any constant-torque crusher/conveyor load above 304.2 N·m decelerates uncontrollably to 0 RPM locked-rotor stall within fractions of a second.
=IF(ISTEXT(E5), E5, LET(ns_r, (120 * B2) / B3, sl_f, (ns_r - B4) / ns_r, ROUND((2 * B6) / ((sl_f / B5) + (B5 / sl_f)), 1)))Try the example
Use the original values or change them to test your understanding.