Atmospheric Dispersion & Air-Permit Modeling, Pasquill-Gifford-Turner (1961) Gaussian Plume

Pasquill-Gifford Gaussian Plume Ground Concentration

Calculate Effective Stack Plume Height Heff (m), Ground-Reflection Vertical Exponential Factor, Downwind Centerline Ground Concentration (ug/m³), and Worst-Case Peak Cmax (ug/m³).

Over-quenching stack gas kills 25 m of buoyant Briggs plume rise—and Because peak ground SO2 scales inversely with Heff^2, losing thermal rise + wind quadruples fence-line exposure

Under the Pasquill-Gifford-Turner (PGT, 1961) Steady-State Gaussian Plume Model with eddy-reflective ground (z = 0) along the wind centerline (y = 0), a continuous point source emitting **Q (g/s = Q * 10⁶ ug/s) from Physical Stack H_s (m) plus Buoyant/Momentum Plume Rise Delta_H (m -> Effective Release Height Heff = H_s + Delta_H m) into Stack-Top Wind Speed u (m/s) produces Ground-Level Centerline Concentration C(x,0,0) = ((Q * 10⁶) / (pi * u * sigma_y * sigma_z)) * exp(-0.5 * (Heff / sigma_z)^2) (ug/m³) across Horizontal/Vertical Dispersion Standard Deviations sigma_y, sigma_z (m). Differentiating with respect to downwind sigma_z (at constant stability ratio sigma_y / sigma_z) locates the Worst-Case Ground Touchdown Peak at sigma_z = Heff / sqrt(2) where Cmax = (2 * Q * 10⁶) / (pi * e * u * (Heff^2) * (sigma_y / sigma_z)) (ug/m³)—scaling inversely with the square of effective stack height**.

Verify on a 55-m Industrial Boiler Stack in Neutral Class D Stability—SO_2_Emission_Rate Q = 45.0 g/s (B2), Physical_Stack H_s = 55.0 m (B3), Buoyant_Plume_Rise Delta_H = 25.0 m (B4), Wind_Speed u = 4.80 m/s (B5), Crosswind_sigma_y = 115 m (B6), and Vertical_sigma_z = 68.0 m (~1.8 km downwind, B7): Effective Stack Height Heff equals 80.0 m (E2), Vertical Reflection Exponential equals 0.5006 (E3), Receptor Ground Concentration equals 191.0 ug/m³ (E4), just below the 202.9 ug/m³ analytical worst-case peak Cmax (E5).

Pasquill-Gifford Gaussian Plume KPI (Q=45 g/s, Hs=55 m, sy=115 m, sz=68 m)FormulaVerified Output
Effective Plume Height Heff (m)Physical_Stack_Hs_m + Plume_Rise_dH_m80.0 m hot stack (58.0 m wet-quenched)
Vertical Ground-Reflection FactorEXP(-0.5 * ((Effective_Heff_m / sz_m) ^ 2))0.5006 (0.6951 fumigating lower)
Centerline Ground Conc (ug/m³)((Q_gs * 1e6) / (PI * u * sy * sz)) * ExpTerm191.0 ug/m³ (670.1 ug/m³ exceedance)
Worst-Case Peak Cmax (ug/m³)(2 * Q_gs * 1e6) / (PI * e * u * Heff^2 * (sy/sz))202.9 ug/m³ (975.0 ug/m³ = 4.8x SPIKE)

Pasquill-Gifford-Turner Ground-Reflected Gaussian Plume & Peak Cmax Formula

Validate Emission_Rate Q > 0 g/s, Stack_Height H_s in [5, 400] m, Plume_Rise dH in [0, 500] m, Wind_Speed u in [0.5, 35.0] m/s, and Dispersion Spreads sigma_y, sigma_z >= 2 m.

=LET(qs_g, B2, hs_m, B3, dh_m, B4, uw_s, B5, sy_m, B6, sz_m, B7, he_m, hs_m + dh_m, IF(OR(qs_g <= 0, hs_m < 5, hs_m > 400, dh_m < 0, dh_m > 500, uw_s < 0.5, uw_s > 35, sy_m < 2, sz_m < 2), "Invalid Plume Input", ROUND((2 * qs_g * 1000000) / (PI() * EXP(1) * uw_s * (he_m ^ 2) * (sy_m / sz_m)), 1)))

Cold Wet-Scrubbed Exhaust (dH = 3 m) + Stagnant 1.9 m/s Wind Fumigation Check

Sub-cool stack gas through a wet scrubber without flue-gas reheat (Delta_H collapses to B4 = 3.0 m -> Heff = 58.0 m in E2) during stagnant B5 = 1.90 m/s morning wind: Receptor SO2 E4 jumps 3.5x to 670.1 ug/m³ while Worst-Case Peak Cmax E5 surges 4.8-fold to 975.0 ug/m³.

=IF(ISTEXT(E5), E5, LET(he_m, B3 + B4, ROUND(((B2 * 1000000) / (PI() * B5 * B6 * B7)) * EXP(-0.5 * ((he_m / B7) ^ 2)), 1)))

Try the example

Use the original values or change them to test your understanding.