Pneumatic Conveying, Powder Transport, Saltation Plugging & Blower Line Sizing
Pneumatic Conveying Gas Velocity & Saltation Margin Formula
Calculate Required Conveying Air Mass Rate (kg/h), Line Volumetric Gas Flow at Pick-Up Pressure (m³/min), Superficial Pick-Up Gas Velocity U_gas (m/s), and Saltation Safety Margin U_gas / U_salt.
Upsizing a pneumatic conveying pipe WITHOUT upsizing the blower drops gas velocity below saltation—plugging the horizontal line solid
In liquid piping, enlarging pipe bore always lowers pressure drop safely; in dilute-phase horizontal pneumatic conveying, enlarging pipe bore D at fixed blower mass flow dot_m_air = dot_m_solids / mu SLASHES Superficial Conveying Gas Velocity U_gas = Q_air / ((PI()/4) * D^2) inversely with D^2. Below the Rizk Saltation Velocity U_salt (m/s, the minimum horizontal gas speed capable of keeping particles in aerodynamic suspension), granules drop out into a stationary dune bed and plug the pipeline within seconds. Reliable dilute-phase design requires Pick-Up Gas Velocity U_gas >= 1.50 * U_salt (Saltation Margin >= 1.50) evaluated at the HIGHEST-PRESSURE (highest gas density rho_air, hence LOWEST velocity) pick-up point directly beneath the rotary airlock.
Verify on a 4-Inch (102 mm ID) Plastic-Pellet Conveying Line—Pipe_Inner_Diameter D = 102.0 mm (B2), Pellet_Throughput dot_m_s = 7,200.0 kg/h (B3), Solids-to-Air_Loading mu = 6.0 (B4 -> Required Air Mass = 1,200.0 kg/h in E2), Pick-Up_Point_Air_Density rho_a = 1.45 kg/m³ (~0.4 bar(g) blower discharge, B5 -> Actual Gas Flow = 13.79 m³/min in E3), and Pellet_Saltation_Velocity U_salt = 14.50 m/s (B6): Pick-Up Superficial Gas Velocity equals 28.13 m/s (E4), providing a healthy 1.94x Saltation Safety Margin (>= 1.50x, E5).
| Dilute-Phase Conveying KPI (ID=102 mm, 7,200 kg/h, mu=6.0, rho_a=1.45 kg/m³) | Formula | Verified Output |
|---|---|---|
| Required Air Mass Flow (kg/h) | Solids_Mass_kg_hr / Loading_Ratio_mu | 1,200.0 kg/h |
| Actual Pick-Up Gas Flow (m³/min) | (Air_Mass_kg_hr / 60) / Air_Density_kg_m3 | 13.79 m³/min |
| Superficial Pick-Up Velocity (m/s) | (Gas_m3_min / 60) / ((PI()/4)*(ID_m^2)) | 28.13 m/s (17.86 m/s @ 128 mm pipe) |
| Saltation Safety Ratio (U / Usalt) | PickUp_Velocity_m_s / Saltation_Vel_m_s | 1.94x (1.23x < 1.50x DANGER @ 128 mm) |
Pick-Up Point Superficial Conveying Gas Velocity & Saltation Margin Formula
Validate Pipe_ID > 15 mm, Solids_Rate > 0 kg/h, Dilute-Phase Loading_mu in (0, 15], Air_Density in [0.5, 10] kg/m³, and Saltation_Velocity > 2 m/s.
=LET(id_m, B2, ms_h, B3, mu_r, B4, ra_k, B5, us_v, B6, IF(OR(id_m <= 15, ms_h <= 0, mu_r <= 0, mu_r > 15, ra_k < 0.5, ra_k > 10, us_v <= 2), "Invalid Conveying Input", LET(ma_h, ms_h / mu_r, qa_s, (ma_h / 3600) / ra_k, ar_p, (PI() / 4) * ((id_m / 1000) ^ 2), ug_s, qa_s / ar_p, ROUND(ug_s / us_v, 2))))Oversized 5-Inch (128 mm ID) Pipe Saltation Danger Check (Set Pipe ID B2 = 128.0 mm)
Swap in a 5" (128.0 mm ID) pipe (B2 = 128) without increasing Roots blower speed: Pick-Up Gas Flow E3 stays 13.79 m³/min, yet Superficial Pick-Up Velocity E4 plunges from 28.13 m/s down to 17.86 m/s, dropping Saltation Margin E5 to 1.23x (< 1.50x safe pickup threshold—risking immediate saltation dune plugging on feed surges).
=IF(ISTEXT(E5), E5, LET(ma_h, B3 / B4, qa_s, (ma_h / 3600) / B5, ar_p, (PI() / 4) * ((B2 / 1000) ^ 2), ROUND(qa_s / ar_p, 2)))Try the example
Use the original values or change them to test your understanding.