Engineering & Science
Redlich-Kwong Real-Gas Equation of State (Pressure & Deviation From Ideal)
Calculate real-gas cylinder & pipeline pressure P = (R*T)/(V_m - b) - a/(SQRT(T)*V_m*(V_m + b)) in MPa using Otto Redlich and Joseph Kwong’s temperature-dependent attractive term.
Redlich-Kwong equation of state for a pure gas
The Redlich-Kwong equation models a pure gas using temperature T, molar volume Vm, and substance-specific constants a and b: P = (R * T) / (Vm - b) - a / (SQRT(T) * Vm * (Vm + b)). It is an approximate equation of state; compare its predictions with validated property data before using them for engineering decisions.
For an illustrative CO2 input (a = 6.46 Pa·m^6·K^0.5/mol^2, b = 0.0000297 m^3/mol), at T = 350 K and Vm = 0.00050 m^3/mol, the ideal-gas law predicts 5.820 MPa. The Redlich-Kwong excluded-volume and attraction terms change the result by approximately +0.368 MPa and −1.304 MPa, giving a model estimate of 4.884 MPa and Z = 0.8391. This is a calculated model example, not a measured pressure.
| CO2 Compression State at T = 350 K (a = 6.46, b = 2.97e-5) | Ideal Pressure RT / Vm (MPa) | Redlich-Kwong Pressure (MPa) | Compressibility Factor Z |
|---|---|---|---|
| Dense CO2 example (Vm = 0.0005 m^3/mol) | 5.820 MPa | 4.884 MPa | 0.8391 (-16.1% Non-Ideal) |
| Moderate Pipeline Gas (Vm = 0.0050 m^3/mol) | 0.582 MPa | 0.572 MPa | 0.9824 (Near-Ideal) |
| Unphysical Compression (Vm <= b) | Hard-Sphere Singularity | "Invalid temperature, volume or parameters" | Excluded-Volume Guard |
Redlich-Kwong Real-Gas Pressure P (MPa)
Evaluates pressure in MPa using T > 0 K, Vm > b, and nonnegative a and b. Inputs must be numeric. Other invalid combinations return an input message rather than attributing every error to volume.
=IF(OR(NOT(ISNUMBER(B2)), NOT(ISNUMBER(B3)), NOT(ISNUMBER(B4)), NOT(ISNUMBER(B5)), B2 <= 0, B3 <= B5, B4 < 0, B5 < 0), "Invalid temperature, volume or parameters", ROUND((((8.31446 * B2) / (B3 - B5)) - (B4 / (SQRT(B2) * B3 * (B3 + B5)))) / 1000000, 3))Dimensionless Real-Gas Compressibility Factor Z = (P * V_m) / (R * T)
Calculates Z = P * Vm / (R * T) from the unrounded modeled pressure; Z = 1 for the ideal-gas model.
=IF(OR(NOT(ISNUMBER(B2)), NOT(ISNUMBER(B3)), NOT(ISNUMBER(B4)), NOT(ISNUMBER(B5)), B2 <= 0, B3 <= B5, B4 < 0, B5 < 0), "Invalid temperature, volume or parameters", ROUND(((((8.31446 * B2) / (B3 - B5)) - (B4 / (SQRT(B2) * B3 * (B3 + B5)))) * B3) / (8.31446 * B2), 4))Try the example
Use the original values or change them to test your understanding.