Arte SheetsLearn. Try. Understand.

Cement, Lime & Mineral Pyroprocessing, USBM Sullivan Rotary Kiln Residence Time

Rotary Kiln Sullivan Residence Time & Fill % Formula

Calculate USBM Sullivan Solids Mean Residence Time (min), Axial Bed Advance Velocity (m/min), In-Kiln Solids Holdup Inventory (tonnes), and Volumetric Fill Degree (%).

Slowing a rotary calciner’s VFD drive from 1.8 to 1.1 RPM stretches residence time 64%—and piles 20 extra tonnes of hot clinker onto the trunnion rollers

Inclined refractory-lined Rotary Kilns, Calciners, and Dryers (Length L m, Inside Brick Diameter D m, Inclination Slope S deg, Shell Speed N RPM) transport granular limestone, alumina, or lithium spodumene of Dynamic Angle of Repose theta (deg) via cascading avalanches down the tumbling chord. Under the classic U.S. Bureau of Mines (USBM) Sullivan Equation (for un-dammed smooth cylindrical kilns), **Mean Solids Residence Time tau = (1.77 * L * SQRT(theta)) / (S * D * N) (min), setting Axial Bed Velocity vax = L / tau** (m/min). At Steady Mass Feed Rate dot_m (t/h, Bulk Density rho_b t/m³), conservation of mass (Mhold = dot_m * (tau / 60) tonnes) means slowing N WITHOUT proportionally cutting feed rate inflates **Volumetric Kiln Fill Degree f% = ((Mhold / rho_b) / ((PI() / 4) * D^2 * L)) * 100%**—risking burner-hood spillage or radial heat-transfer starvation above ~12%–15% fill.

Verify on a 55.0 m Lime Calcining Rotary Kiln—Refractory_Length L = 55.0 m (B2), Inside_Brick_Diameter D = 3.40 m (B3), Shell_Slope S = 2.20° (B4), Drive_Speed N = 1.80 RPM (B5), Limestone_Repose_Angle theta = 38.0° (B6), Kiln_Feed_Rate = 42.0 t/h (B7), and Bed_Bulk_Density rho_b = 1.35 t/m³ (B8): Mean Residence Time equals 44.57 min (E2), Axial Velocity runs 1.234 m/min (E3), Hot Holdup Inventory equals 31.20 tonnes (E4), and Volumetric Fill sits in the optimal rolling-cascade regime at 4.63% (E5).

USBM Sullivan Rotary Kiln KPI (L=55 m, D=3.4 m, S=2.2°, theta=38°, 42 t/h, N=1.8 vs 1.1 RPM)FormulaVerified Output
Mean Residence Time tau (min)(1.77 * L_m * SQRT(theta_deg)) / (S_deg * D_m * N)44.57 min (72.93 min @ N=1.1 RPM)
Axial Bed Velocity (m/min)Kiln_Length_L_m / Residence_Time_min1.234 m/min (0.754 m/min @ N=1.1 RPM)
In-Kiln Solids Holdup (tonnes)Feed_Rate_t_h * (Residence_Time_min / 60)31.20 t (51.05 t trunnion load @ 1.1 RPM)
Volumetric Fill Degree (%)((Holdup_t / Bulk_rho) / ((PI()/4)*D^2*L))*1004.63% (7.57% deeper bed @ 1.1 RPM)

USBM Sullivan Tumbling-Cascade Residence Time, Holdup & Fill Degree Formula

Validate Length L > 3 m, Diameter D > 0.3 m, Slope S in [0.3°, 8.0°], Speed N in (0.1, 15.0] RPM, Repose_Angle theta in [15°, 55°], Feed > 0 t/h, and Bulk_Density > 0.2 t/m³.

=LET(lk_m, B2, dk_m, B3, sl_d, B4, nr_p, B5, th_d, B6, fd_t, B7, rb_t, B8, tr_m, (1.77 * lk_m * SQRT(th_d)) / (sl_d * dk_m * nr_p), mh_t, fd_t * (tr_m / 60), vk_m, (PI() / 4) * (dk_m ^ 2) * lk_m, IF(OR(lk_m <= 3, dk_m <= 0.3, sl_d < 0.3, sl_d > 8, nr_p <= 0.1, nr_p > 15, th_d < 15, th_d > 55, fd_t <= 0, rb_t <= 0.2), "Invalid Kiln Input", ROUND(((mh_t / rb_t) / vk_m) * 100, 2)))

Slowed 1.1 RPM Shell Speed Holdup Surge Check (Set Kiln Speed B5 = 1.1 RPM)

Turn down kiln rotation from 1.80 to 1.10 RPM (B5 = 1.1) while holding 42.0 t/h raw stone feed: Residence Time E2 jumps to 72.93 min, Live Bed Inventory E4 swells by +19.85 tonnes to 51.05 t, and Volumetric Fill E5 climbs to 7.57%—explaining why modern DCS kiln controllers ratio-link weigh-belt feed t/h directly to kiln RPM.

=IF(ISTEXT(E5), E5, ROUND((1.77 * B2 * SQRT(B6)) / (B4 * B3 * B5), 2))

Try the example

Use the original values or change them to test your understanding.

Further reading