Process Safety, ASME Section VIII UG-127 & Rupture Disks
Rupture Disk: Manufacturing Range and Burst Tolerance
Distinguish a manufacturing design range from a tolerance around a marked burst pressure using a manufacturer’s illustrative example.
Two different pressure ranges
A manufacturing design range is an agreed range within which a lot’s marked burst pressure may fall. Burst tolerance describes an allowed deviation around the marked pressure at a specified disk temperature. They are different concepts: a tolerance around one marked value does not have to lie inside the manufacturing design range.
For one product example, BS&B describes a desired pressure of 80 psig with a manufacturing range of −5 psi to +9 psi: the marked pressure is therefore between 75 and 89 psig. If an actual lot is marked 78 psig and the applicable burst tolerance is ±5%, arithmetic gives 74.10 to 81.90 psig around that mark. These values illustrate the terminology in that product example, not a universal tolerance or a device selection.
| Illustrative quantity | Arithmetic | Result |
|---|---|---|
| Manufacturing range for marked pressure | 80 − 5 to 80 + 9 psig | 75 to 89 psig |
| Tolerance interval around 78 psig mark | 78 × (1 − 0.05) to 78 × (1 + 0.05) | 74.10 to 81.90 psig |
Calculate the illustrative intervals
Enter the desired pressure, the lower and upper manufacturing allowances in psi, a marked pressure in that range, and an illustrative symmetric tolerance as a percentage. The sheet computes the two arithmetic intervals. Product specifications can use different ranges, tolerances or conventions; use the actual manufacturer data and governing requirements.
=IF(COUNT(B2:B6)<>5,"Enter all numeric inputs",IF(OR(B2<=0,B3<0,B3>B2,B4<0,B5<B2-B3,B5>B2+B4,B6<0,B6>=100),"Check example inputs",ROUND(B5*(1+B6/100),2)))Do not use the arithmetic as an acceptance decision
A marked burst pressure is associated with a specified disk temperature; a single assumed temperature multiplier does not establish behavior at other conditions. Disc material, type, medium, operating conditions, manufacturing range and burst tolerance need to be assessed for the actual device.
A rupture disk installed with a relief valve also affects the system’s capacity and pressure losses. An assumed combination factor or a simple comparison with vessel pressure does not establish code compliance or safe relief. Qualified personnel should use applicable current standards, manufacturer documentation, certified combination data and the project’s complete relief-system design.
Try the example
Use the original values or change them to test your understanding.