Healthcare & Clinical Formulas
Scatchard Plot: A Synthetic Binding-Equation Example
Learn the slope and intercept relationship of a single-site Scatchard transformation with synthetic data, and understand why actual binding data are normally fit by nonlinear regression.
The one-site equation
For a reversible single-site equilibrium model, specific binding B = Bmax × F / (Kd + F), where F is the free ligand concentration. Algebra gives B/F = −B/Kd + Bmax/Kd. A plot of B/F versus B is a straight line for ideal model-generated data: its slope is −1/Kd and its x-intercept is Bmax. Kd uses the units of F; Bmax uses the units in which specific binding B was measured.
The four data points below are deliberately noiseless and illustrate algebra only. For real experiments, the transformation shares B between both axes and changes the error distribution; ordinary regression on a Scatchard plot can yield biased estimates. Fit an appropriate binding model to the untransformed experimental data by nonlinear regression and account for nonspecific binding and ligand depletion where needed. A nonnegative fitted slope alone does not establish cooperativity.
| Free F (nM) | Specific bound B (fmol/mg) | B/F |
|---|---|---|
| 1.25 | 24 | 19.2 |
| 5.00 | 60 | 12.0 |
| 15.00 | 90 | 6.0 |
| 45.00 | 108 | 2.4 |
Calculate a teaching-only Kd from the line
Enter positive free concentrations in A2:A5, nonnegative specific binding values in B2:B5, and the B/F ratios in C2:C5. The example returns 5.00 nM. Input and slope checks only prevent basic invalid arithmetic; they cannot verify equilibrium, the binding model or experimental quality.
=IF(COUNT(A2:B5)<>8,"Enter numeric F and B",IF(OR(MIN(A2:A5)<=0,MIN(B2:B5)<0,MAX(B2:B5)=MIN(B2:B5)),"Check F and B",IF(COUNT(C2:C5)<>4,"Check B/F ratios",IF(SLOPE(C2:C5,B2:B5)>=0,"Slope must be negative",IF(INTERCEPT(C2:C5,B2:B5)<=0,"Check intercept",ROUND(-1/SLOPE(C2:C5,B2:B5),2))))))Calculate a teaching-only Bmax from the intercept
The synthetic line has a Bmax of 120.0 fmol/mg. If a different assay uses a different binding or surface-response unit, Bmax retains that unit; do not interpret a sensor response as receptor density without an appropriate calibration.
=IF(COUNT(A2:B5)<>8,"Enter numeric F and B",IF(OR(MIN(A2:A5)<=0,MIN(B2:B5)<0,MAX(B2:B5)=MIN(B2:B5)),"Check F and B",IF(COUNT(C2:C5)<>4,"Check B/F ratios",IF(SLOPE(C2:C5,B2:B5)>=0,"Slope must be negative",IF(INTERCEPT(C2:C5,B2:B5)<=0,"Check intercept",ROUND(-INTERCEPT(C2:C5,B2:B5)/SLOPE(C2:C5,B2:B5),1))))))Try the example
Use the original values or change them to test your understanding.