Mechanical Design & Fasteners
Bolted Joint: An Illustrative Linear-Spring Load Share
Calculate a simplified pre-separation load share and a modelled separation threshold while identifying the assumptions and design limitations.
The idealised linear-spring model
In a simplified preloaded joint under an axial separating load, a linear-spring model can estimate how the bolt load and member compression change before the model predicts separation. Let the bolt stiffness be k_b, the clamped-member stiffness be k_m, and the initial preload be F_i. For the particular load-introduction assumption used here, C = k_b/(k_b+k_m), the model bolt force is F_i + CP, and remaining member compression is F_i − (1−C)P.
The example assumes a single effective axial load P at a specified load-introduction location corresponding to factor n = 1, linear elastic stiffness, unchanged preload and no bending or prying. NASA’s bolted-joint standard includes a load-introduction factor n because joint geometry and the location where the load enters affect load sharing. These assumptions are not general properties of all flanges or bolted assemblies.
With k_b = 500 kN/mm, k_m = 1,500 kN/mm, F_i = 45,000 N and P = 24,000 N, C = 0.25. The idealised bolt force is 51,000 N and the remaining member compression is 27,000 N. The model predicts its zero-compression threshold at P = F_i/(1−C) = 60,000 N. The ratio of that threshold to the chosen load is 2.5; it is not a complete design safety factor.
| Model quantity | Formula under n = 1 assumption | Illustrative result |
|---|---|---|
| Stiffness factor C | k_b / (k_b + k_m) | 0.25 |
| Bolt force before separation | F_i + C P | 51,000 N |
| Remaining member compression | F_i − (1 − C) P | 27,000 N |
| Model zero-compression threshold | F_i / (1 − C) | 60,000 N |
Scope of the worksheet
Enter positive stiffnesses and preload and a nonnegative external axial load. E2 calculates the stiffness factor and E5 the idealised zero-compression threshold. E3 and E4 report the two force estimates only while P is below that threshold; at or beyond it they return a message. E6 gives the model threshold divided by P, and is undefined at P = 0.
This worksheet does not calculate the response after separation. It also does not establish gasket sealing, prevent leakage, or account for force distribution among multiple bolts.
=IF(ISNUMBER(E2),IF(B5>=E5,"At or beyond model separation",B4+E2*B5),E2)Engineering checks beyond this model
Actual joints can be affected by load-introduction geometry, preload uncertainty and loss, thermal expansion, prying, bending, shear, fatigue, thread strength and gasket requirements. A positive model compression or a threshold-to-load ratio above one does not prove a joint safe or sealed. Use a qualified design assessment and the governing requirements for the application.
Try the example
Use the original values or change them to test your understanding.