Arte SheetsLearn. Try. Understand.

Mechanical Design & Fasteners

Bolted Joint: An Illustrative Linear-Spring Load Share

Calculate a simplified pre-separation load share and a modelled separation threshold while identifying the assumptions and design limitations.

The idealised linear-spring model

In a simplified preloaded joint under an axial separating load, a linear-spring model can estimate how the bolt load and member compression change before the model predicts separation. Let the bolt stiffness be k_b, the clamped-member stiffness be k_m, and the initial preload be F_i. For the particular load-introduction assumption used here, C = k_b/(k_b+k_m), the model bolt force is F_i + CP, and remaining member compression is F_i − (1−C)P.

The example assumes a single effective axial load P at a specified load-introduction location corresponding to factor n = 1, linear elastic stiffness, unchanged preload and no bending or prying. NASA’s bolted-joint standard includes a load-introduction factor n because joint geometry and the location where the load enters affect load sharing. These assumptions are not general properties of all flanges or bolted assemblies.

With k_b = 500 kN/mm, k_m = 1,500 kN/mm, F_i = 45,000 N and P = 24,000 N, C = 0.25. The idealised bolt force is 51,000 N and the remaining member compression is 27,000 N. The model predicts its zero-compression threshold at P = F_i/(1−C) = 60,000 N. The ratio of that threshold to the chosen load is 2.5; it is not a complete design safety factor.

Model quantityFormula under n = 1 assumptionIllustrative result
Stiffness factor Ck_b / (k_b + k_m)0.25
Bolt force before separationF_i + C P51,000 N
Remaining member compressionF_i − (1 − C) P27,000 N
Model zero-compression thresholdF_i / (1 − C)60,000 N

Scope of the worksheet

Enter positive stiffnesses and preload and a nonnegative external axial load. E2 calculates the stiffness factor and E5 the idealised zero-compression threshold. E3 and E4 report the two force estimates only while P is below that threshold; at or beyond it they return a message. E6 gives the model threshold divided by P, and is undefined at P = 0.

This worksheet does not calculate the response after separation. It also does not establish gasket sealing, prevent leakage, or account for force distribution among multiple bolts.

=IF(ISNUMBER(E2),IF(B5>=E5,"At or beyond model separation",B4+E2*B5),E2)

Engineering checks beyond this model

Actual joints can be affected by load-introduction geometry, preload uncertainty and loss, thermal expansion, prying, bending, shear, fatigue, thread strength and gasket requirements. A positive model compression or a threshold-to-load ratio above one does not prove a joint safe or sealed. Use a qualified design assessment and the governing requirements for the application.

Try the example

Use the original values or change them to test your understanding.

Further reading