SMT Electronics Assembly, SAC305 Lead-Free Reflow Profiling & IPC/JEDEC J-STD-020
SMT Reflow Oven Belt Speed, Ramp Slope & TAL Formula
Calculate Preheat Zone Residence Time (s), Preheat Thermal Ramp Slope (°C/s <= 3.0 °C/s limit), Peak Zone Time Above 217 °C SAC305 Liquidus TAL (s), and J-STD-020 Profile Audit.
Cranking reflow conveyor speed up to chase SMT line beat rate slashes TAL below 45 seconds—causing cold head-in-pillow BGA joints AND thermal-shock tombstoning
In a multi-zone forced-convection SMT reflow tunnel running at Mesh/Pin Conveyor Speed v_belt (cm/min -> v_belt / 60 cm/s), every PCB thermocouple profile balances TWO opposing IPC/JEDEC J-STD-020 limits for lead-free SAC305 (Sn 96.5Ag3.0Cu0.5, melting liquidus 217 °C): (1) Preheat Ramp Slope Slope = (T_soak - T_amb) / (L_preheat / (v_belt / 60)) MUST stay <= 3.0 °C/s (1.5–2.5 °C/s ideal) so ceramic MLCC capacitors do not crack and volatile flux solvents do not boil explosively ("solder balling" / 0402 tombstoning), and (2) Time Above Liquidus (TAL) t_TAL = L_above_217 / (v_belt / 60) MUST land inside 45 to 90 seconds (< 45 s fails to wet CuOSP/ENIG pads into a sound Cu6Sn5 intermetallic layer; > 90 s grows thick brittle intermetallic and delaminates IC packages).
Verify on a 10-Zone Lead-Free SAC305 Convection Oven—Conveyor_Speed v_belt = 80.0 cm/min (1.333 cm/s, B2), Preheat_Ramp_Length L_pre = 96.0 cm (B3 -> Preheat Dwell = 72.00 s in E2), Room_Entry_Temp T_amb = 25.0 °C (B4), Flux_Soak_Entry_Temp T_soak = 155.0 °C (B5 -> Ramp Slope = 1.81 °C/s <= 3.0 °C/s in E3), and Effective_Tunnel_Length_Above_217C L_TAL = 84.0 cm (B6): Time Above Liquidus equals 63.00 s (E4), passing "J-STD-020 SAC305 PASS" (E5).
| IPC/JEDEC J-STD-020 Reflow KPI (Belt=80 cm/min, L_pre=96 cm, L_TAL=84 cm) | Formula | Verified Output |
|---|---|---|
| Preheat Zone Residence (sec) | Preheat_Len_cm / (Belt_cm_min / 60) | 72.00 s (46.08 s @ 125 cm/min rush) |
| Preheat Ramp Slope (°C/s) | (T_soak_C - T_amb_C) / Preheat_Time_s | 1.81 °C/s (2.82 °C/s @ 125 cm/min) |
| Time Above 217°C Liquidus TAL (s) | Peak_217_Len_cm / (Belt_cm_min / 60) | 63.00 s (40.32 s < 45s @ 125 cm/min) |
| J-STD-020 SAC305 Window Gate | Slope <= 3.0 AND 45 <= TAL <= 90 | J-STD-020 SAC305 PASS |
Conveyor Residence Time, Thermal Ramp Slope & SAC305 TAL Window Formula
Validate Belt_Speed in (10, 300] cm/min, Preheat_Len > 0 cm, 0 <= T_amb < T_soak <= 217 °C, and Peak_Above_217_Len > 0 cm right on E2 (checking ISTEXT(E2) on E3..E4 so text status strings in E5 never block numeric cells).
=LET(vb_m, B2, lp_c, B3, ta_c, B4, ts_c, B5, lt_c, B6, IF(OR(vb_m <= 10, vb_m > 300, lp_c <= 0, ta_c < 0, ts_c <= ta_c, ts_c > 217, lt_c <= 0), "Invalid Reflow Input", LET(vc_s, vb_m / 60, tp_s, lp_c / vc_s, sl_p, (ts_c - ta_c) / tp_s, tl_s, lt_c / vc_s, IF(AND(sl_p <= 3, tl_s >= 45, tl_s <= 90), "J-STD-020 SAC305 PASS", "OUT OF REFLOW WINDOW"))))Over-Sped 125 cm/min Conveyor Cold-Solder Wetting Failure Check (Set Belt Speed B2 = 125.0 cm/min)
Speed the mesh belt up from 80.0 to 125.0 cm/min (B2 = 125) without lengthening peak zones: Preheat Time E2 shrinks to 46.08 s (Ramp = 2.82 °C/s in E3), and Time Above Liquidus E4 drops to 40.32 s (< 45 s minimum wetting time)—flagging "OUT OF REFLOW WINDOW" in E5.
=IF(ISTEXT(E2), E2, ROUND(B6 / (B2 / 60), 2))Try the example
Use the original values or change them to test your understanding.