Healthcare & Clinical
Systemic and Pulmonary Vascular Resistance: Pressure, Flow and Units
Explore pressure-gradient-to-flow calculations in Wood units and dyn·s·cm⁻⁵, with complete input checks and context about their clinical limitations.
Pressure difference divided by flow
A commonly used approximation of systemic vascular resistance is (mean arterial pressure − right atrial pressure) / cardiac output. Central venous pressure is often used as a right atrial pressure estimate under suitable conditions. Pulmonary vascular resistance is commonly expressed as (mean pulmonary artery pressure − pulmonary artery wedge pressure) / pulmonary blood flow.
With pressures in mmHg and flow in L/min, the ratio is in Wood units (mmHg·min/L). Multiplying by approximately 80 expresses it in dyn·s·cm⁻⁵. The example uses one flow value for both calculations, an assumption that may not hold when pulmonary and systemic flows differ, such as with a significant shunt.
Neither number alone diagnoses a type of shock or pulmonary arterial hypertension. The 2022 ESC/ERS framework considers pulmonary arterial pressure, wedge pressure and resistance together; identifying the cause requires further clinical evaluation. The linked sources discuss measurement and interpretation.
Systemic resistance example
For this fictional arithmetic example, B2 is mean arterial pressure in mmHg, B3 the central venous pressure estimate in mmHg, and B4 the assumed flow in L/min. All three inputs must be numeric. A nonpositive flow or pressure gradient prompts a check instead of producing a number; the prompt is not a diagnosis of why a measurement differs.
=IF(COUNT(B2:B4)<>3,"Enter the three numeric systemic inputs",IF(B4<=0,"Enter a positive flow",IF(B2<=B3,"Review the systemic pressure gradient",ROUND(80*(B2-B3)/B4,1))))Pulmonary resistance in dyn·s·cm⁻⁵
B5 and B6 contain mean pulmonary arterial and wedge pressures in mmHg, and B4 the assumed pulmonary flow. This calculation requires those three inputs independently of the systemic pressure values.
=IF(COUNT(B4:B6)<>3,"Enter the three numeric pulmonary inputs",IF(B4<=0,"Enter a positive flow",IF(B5<=B6,"Review the pulmonary pressure gradient",ROUND(80*(B5-B6)/B4,1))))The same ratio in Wood units
Use the unrounded pressure difference divided by flow, rather than dividing the rounded result above. This spreadsheet illustrates arithmetic only and is not a clinically validated decision tool.
=IF(COUNT(B4:B6)<>3,"Enter the three numeric pulmonary inputs",IF(B4<=0,"Enter a positive flow",IF(B5<=B6,"Review the pulmonary pressure gradient",ROUND((B5-B6)/B4,2))))Try the example
Use the original values or change them to test your understanding.