Arte SheetsLearn. Try. Understand.

Architectural & Automotive Glazing Engineering, ASTM C1048 Thermal Glass Tempering

Thermal Glass Tempering Quench Stress & ASTM C1048 Formula

Calculate Half-Plate Air-Quench Biot Number Bi, Parabolic Surface Compressive Residual Stress (MPa), Mid-Plane Core Tensile Stress (MPa), and ASTM C1048 / EN 12150 Safety Glass Class.

Why 3 mm thin glass needs MORE than 2x the air-jet blower pressure of 6 mm float glass to lock in 69 MPa ASTM C1048 safety temper

Thermal Glass Tempering heats soda-lime-silica float glass (Thickness d mm, Thermal Conductivity k = 1.05 W/(m·K), **Thermoelastic Constant beta = (alpha * E) / (1 - nu) ~= 0.82 MPa/K) above its ~620°C softening point and blasts both faces with high-velocity air-quench nozzles (Heat-Transfer Coefficient h W/(m²·K)). While the outer skins freeze rigid below the ~550°C glass transition T_g, the hot viscoelastic core stays Delta_T_f (K) hotter; when the core finally cools to room temperature and tries to contract, the already-rigid skins resist it—locking in a Parabolic Residual Stress Profile with Surface Compression sigmasurf = (2 / 3) * beta * Delta_T_f (MPa, exact 2:1 equilibrium against Mid-Plane Core Tension sigmacore = sigmasurf / 2 MPa). Because Delta_T_f scales with Half-Thickness Quench Biot Number Bi = (h * (d / 2)) / k, halving glass thickness d halves Bi unless quench jet h doubles. Per ASTM C1048, Fully Tempered (FT) safety glass requires sigmasurf >= 69 MPa** (10,000 psi, shattering into blunt dicing cubes instead of dagger shards).

Verify on a 6.0 mm Automotive Side-Lite Air Quench—Glass_Thickness d = 6.0 mm (B2 -> half-thickness a = 0.003 m), Quench_Blower_HTC h = 340 W/(m²·K) (B3), Glass_Conductivity k = 1.05 W/(m·K) (B4), Frozen_Surface-to-Core_Temp_Lag Delta_T_f = 155 K (B5), and Thermoelastic_Modulus_Factor beta = 0.82 MPa/K (B6): Quench Biot Number equals 0.971 (E2), Surface Compression reaches 84.73 MPa (>= 69 MPa. E3), Balanced Mid-Plane Core Tension equals 42.37 MPa (E4), certifying "ASTM C1048 FULLY TEMPERED" (E5).

ASTM C1048 Glass Tempering KPI (6 mm Soda-Lime Float, k=1.05 W/m·K, beta=0.82 MPa/K)FormulaVerified Output
Half-Plate Quench Biot Number Bi(Quench_h * (Thickness_mm / 2000)) / Glass_k0.971 (0.457 weak quench @ h=160)
Surface Compressive Stress (MPa)(2 / 3) * Thermoelastic_beta * Frozen_dT_K84.73 MPa (44.83 MPa heat-strengthened)
Mid-Plane Core Tension (MPa)Surface_Compression_MPa / 2 (Parabolic 2:1)42.37 MPa (22.41 MPa core tension)
ASTM C1048 Glazing ClassificationSurface_Compression >= 69 MPa FT Safety GateASTM C1048 FULLY TEMPERED

Gardon Thermoelastic Air-Quench Biot Number & Parabolic 2:1 Temper Stress Formula

Validate Thickness d in [2.0, 25.0] mm, Quench_HTC h in [20, 1,500] W/(m²·K), Conductivity k in [0.5, 2.5] W/(m·K), Frozen dT in [10, 350] K, and beta in [0.3, 1.5] MPa/K right on E2 (checking ISTEXT(E2) on E3..E4 so E5 text stays decoupled).

=LET(dm_m, B2, hq_w, B3, kg_w, B4, dt_k, B5, bt_m, B6, sc_m, (2 / 3) * bt_m * dt_k, IF(OR(dm_m < 2, dm_m > 25, hq_w < 20, hq_w > 1500, kg_w < 0.5, kg_w > 2.5, dt_k < 10, dt_k > 350, bt_m < 0.3, bt_m > 1.5), "Invalid Tempering Input", IF(sc_m >= 69, "ASTM C1048 FULLY TEMPERED", "BELOW 69 MPa TEMPER FLOOR")))

Low-Pressure Heat-Strengthening Quench (h = 160 W/m²·K, dT = 82 K) Non-Safety Check

Throttle quench blower static pressure for curtain-wall spandrel Heat-Strengthened (HS, 24–52 MPa) glass (B3 = 160, B5 = 82 K): Biot Number E2 drops to 0.457, Surface Compression E3 falls to 44.83 MPa (22.41 MPa core tension in E4), and E5 warns "BELOW 69 MPa TEMPER FLOOR"—prohibited in frameless doors or automotive glazing because break pattern reverts to large shards.

=IF(ISTEXT(E2), E2, ROUND((2 / 3) * B6 * B5, 2))

Try the example

Use the original values or change them to test your understanding.

Further reading