Naval Architecture & Towage Engineering, ASD Tugboat Static Bollard Pull & Ducted Nozzles
Tugboat Static Bollard Pull & Ducted Nozzle Thrust Formula
Calculate Total Swept Propeller Disk Area (m²), Certified Continuous Bollard Pull (tonnes), Specific Thrust Efficiency (kg/kW), and Storm Towline Reserve Margin (%).
Static tugboat thrust scales as Power^(2/3)—so surrounding twin propellers with airfoil nozzles adds 39% MORE bollard pull without bigger diesel engines
At zero forward speed (V_a = 0 static pier trial), classical propeller efficiency T * V_a / P_D is identically zero—so naval architects govern Harbor & Offshore Tugboat Bollard Pull by Rankine-Bendemann Static Actuator-Disk Momentum Theory in Seawater (rho = 1,025 kg/m³). Across N_p propellers of Diameter D (m, Swept Disk Area per Screw A_1 = (PI() / 4) * D^2 m²) absorbing Total Shaft Power P_D (kW -> P_1 = (P_D * 1,000) / N_p W per shaft) with Bendemann Figure of Merit FM (~0.54–0.58 for open propellers where slipstream vena-contracta contracts to A / 2, vs 0.75–0.82 for accelerating airfoil ducted nozzles that suppress tip-vortex contraction and carry ~40% of thrust directly on the nozzle lip), **Continuous Bollard Pull BP = (N_p * FM * (2 * 1,025 * A_1 * P_1^2)^{1/3}) / 9,806.65** (tonnes-force).
Verify on a 4,200 kW (5,632 bhp) Twin-Z-Drive (ASD) Harbor Assist Tug—Total_Delivered_Power P_D = 4,200 kW (B2), Azimuth_Thrusters N_p = 2 (B3), Propeller_Diameter D = 2.80 m (B4 -> Total Swept Disk Area = 12.32 m² in E2), Ducted-Nozzle_Figure_of_Merit FM = 0.78 (B5), and Required_Storm_Escort_Pull = 48.0 tonnes (B6): Continuous Bollard Pull hits 60.74 tonnes (E3), Specific Efficiency reaches 14.46 kg/kW (E4), providing a +26.5% storm reserve margin (E5).
| ASD Harbor Tug Bollard-Pull KPI (4,200 kW, Twin 2.80 m Screws: Ducted FM=0.78 vs Open FM=0.56) | Formula | Verified Output |
|---|---|---|
| Total Swept Disk Area (m²) | Prop_Count * (PI() / 4) * (Prop_D_m ^ 2) | 12.32 m² |
| Continuous Bollard Pull (tonnes) | (Np * FM * (2*1025*A1*P1_W^2)^(1/3)) / 9806.65 | 60.74 t (43.61 t @ open propeller) |
| Specific Bollard Efficiency (kg/kW) | (Bollard_Pull_tonnes * 1000) / Shaft_Power_kW | 14.46 kg/kW (10.38 kg/kW @ open screw) |
| Storm Tow Reserve Margin (%) | ((Bollard_Pull_t - Req_Tow_t) / Req_Tow_t) * 100 | +26.5% (-9.2% DEFICIT without nozzles) |
Bendemann Static Actuator-Disk Thrust (P^(2/3) * A^(1/3)) & Tow Margin Formula
Validate Shaft_Power P_D > 100 kW, integer Propellers N_p in [1, 4], Diameter D in [0.8, 6.0] m, Figure_of_Merit FM in [0.40, 0.90], and Required_Tow > 1 t.
=LET(pd_k, B2, np_c, B3, dp_m, B4, fm_b, B5, rt_t, B6, a1_m, (PI() / 4) * (dp_m ^ 2), p1_w, (pd_k * 1000) / np_c, ti_n, (2 * 1025 * a1_m * (p1_w ^ 2)) ^ (1 / 3), bp_t, (np_c * fm_b * ti_n) / 9806.65, IF(OR(pd_k <= 100, np_c < 1, np_c > 4, dp_m < 0.8, dp_m > 6, fm_b < 0.4, fm_b > 0.9, rt_t <= 1), "Invalid Tug Input", ROUND(((bp_t - rt_t) / rt_t) * 100, 1)))Un-Ducted Open-Wheel Propeller (FM = 0.56) Storm-Tow Deficit Check (Set FM B5 = 0.56)
Remove the accelerating shroud nozzles (FM drops to open-wheel B5 = 0.56 on the identical 4,200 kW diesels): Bollard Pull E3 plunges -28.2% to 43.61 tonnes (10.38 kg/kW in E4), flipping Storm Tow Reserve E5 negative (-9.2%)—requiring 6,800+ kW of fuel-thirsty main engines to match what 2.80 m nozzles achieve at 4,200 kW.
=IF(ISTEXT(E5), E5, LET(a1_m, (PI() / 4) * (B4 ^ 2), p1_w, (B2 * 1000) / B3, ti_n, (2 * 1025 * a1_m * (p1_w ^ 2)) ^ (1 / 3), ROUND((B3 * B5 * ti_n) / 9806.65, 2)))Try the example
Use the original values or change them to test your understanding.