High-Vacuum, Semiconductor Tooling & Particle Accelerator Engineering, UHV Wall Outgassing
UHV Chamber Outgassing Load & Ultimate Base Pressure Formula
Calculate Power-Law Wall Outgassing Gas Load Q(t) (10⁻⁶ mbar·L/s), Ultimate Chamber Base Pressure P_base (10⁻⁹ mbar), Area-Specific Pumping Speed (L/s·m²), and UHV Target Ratio.
Below 10⁻⁴ mbar, chamber volume stops mattering—adsorbed water monolayers desorbing off stainless-steel walls set your ultimate vacuum floor
Once roughing and turbomolecular pumps evacuate bulk air out of a 304L/316L stainless-steel High-Vacuum (HV) / Ultra-High-Vacuum (UHV) chamber (Internal Surface Area A cm², Conductance-Throttled Effective Pumping Speed Seff L/s), pressure stalls along a 1/t plateau governed by Thermal Desorption Outgassing of 50–100 monolayers of adsorbed water vapor (H_2O binding energy ~0.8–1.0 eV). Unbaked stainless steel exhibits a 1-Hour Specific Outgassing Rate q_1 ~= 3.0 x 10⁻⁹ mbar·L/(s·cm²) (30 x 10⁻¹⁰ units) decaying hyperbolically with pumpdown hours t as q(t) = q_1 / t^alpha (alpha ~= 1.0 for water desorption), creating **Total Outgassing Load Q(t) = q(t) * A (mbar·L/s) and clamping Ultimate Base Pressure at Pbase = Q(t) / Seff (mbar)—which only a 150–250°C UHV Bakeout** (75x–1,000x drop in q_1 down to dissolved H_2 diffusion) can break through.
Start on an Unbaked 4.50 m² (45,000 cm²) MBE / Synchrotron Beamline Vessel—1-Hour_Outgassing_Rate q_1 = 32.0 x 10⁻¹⁰ mbar·L/(s·cm²) (B2), Internal_Wall_Area A = 45,000 cm² (B3), Pumpdown_Time t = 10.0 h (B4), Desorption_Decay_Exponent alpha = 1.00 (B5), and Throttled_Effective_Speed Seff = 420 L/s (B6). Ask the in-app assistant for a gas-throughput balance hint (Q = P * S): Total Outgassing Load equals 14.400 x 10⁻⁶ mbar·L/s (E2), Ultimate Base Pressure stalls at 34.286 x 10⁻⁹ mbar (3.43 x 10⁻⁸ mbar, E3), Area-Specific Pumping Speed equals 93.33 L/(s·m²) (E4), sitting 685.71x above a 0.05 x 10⁻⁹ mbar (5 x 10⁻¹¹ mbar) UHV target (E5).
| UHV Outgassing Balance KPI (A=45,000 cm², t=10 h, S_eff=420 L/s) | Formula | Verified Output |
|---|---|---|
| Wall Gas Load Q (10⁻⁶ mbar·L/s) | ((q1_1e10 * 1e-10 * Area_cm2) / (t^alpha)) * 1e6 | 14.400 (0.189 after 200°C bakeout) |
| Ultimate Base Pressure (10⁻⁹ mbar) | (Gas_Load_mbar_L_s / Seff_L_s) * 1e9 | 34.286 nbar? 3.43e-8 mbar (0.450e-9 baked) |
| Area-Specific Speed (L/(s·m²)) | Seff_L_s / (Wall_Area_cm2 / 10000) | 93.33 L/(s·m²) |
| Multiple of 5x10⁻¹¹ mbar UHV Gate | Base_Pressure_1e9_mbar / 0.05 | 685.71x unbaked (9.00x baked) |
Dayton Power-Law Water Desorption Outgassing & Throughput Base-Pressure Formula
Validate 1h_Outgassing q_1 > 0 (x 10⁻¹⁰ mbar·L/s·cm²), Wall_Area A >= 100 cm², Pumpdown_Time t >= 0.1 h, Decay_Exponent alpha in [0.3, 1.5], and Effective_Pumping_Speed Seff > 1 L/s.
=LET(q1_u, B2, aw_c, B3, tp_h, B4, al_p, B5, se_l, B6, qt_m, ((q1_u * 0.0000000001) * aw_c) / (tp_h ^ al_p), pb_9, (qt_m / se_l) * 1000000000, IF(OR(q1_u <= 0, aw_c < 100, tp_h < 0.1, al_p < 0.3, al_p > 1.5, se_l <= 1), "Invalid Outgas Input", ROUND(pb_9 / 0.05, 2)))48-Hour 200°C Bakeout Water-Stripping Gain Check (Set q1 B2 = 0.42 x 10⁻¹⁰)
Wrap heating jackets around the chamber for a 200°C bakeout so adsorbed H_2O desorbs and q_1 drops 76x to B2 = 0.42 (4.2 x 10⁻¹¹ mbar·L/s·cm²): Gas Load E2 plummets to 0.189 x 10⁻⁶ mbar·L/s and Base Pressure E3 plunges into true UHV at 0.450 x 10⁻⁹ mbar (4.5 x 10⁻¹⁰ mbar, E5 = 9.00x)—ready for Ti-sublimation / NEG getter firing.
=IF(ISTEXT(E5), E5, LET(qt_m, ((B2 * 0.0000000001) * B3) / (B4 ^ B5), ROUND((qt_m / B6) * 1000000000, 3)))Try the example
Use the original values or change them to test your understanding.