Ultrasonic Plastic Welding Horn Gain & Heating Formula

Calculate Acoustic Stack Peak-to-Peak Horn Amplitude (um), Peak Sonotrode Tip Velocity (m/s), Energy-Director Cyclic Strain Amplitude, and Viscoelastic Melt Power (W).

Viscoelastic ultrasonic weld heating scales with the SQUARE of booster-horn amplitude—swapping a 1.5x gold booster for a 1.0x green booster cuts melt power 7.5x

Ultrasonic Plastic Welding (20, 30, or 35 kHz Frequency f kHz) converts piezoelectric PZT transducer vibrations of Zero-to-Peak Converter Amplitude A_0 (um, typically 10 um = 20 um peak-to-peak at 20 kHz) through a half-wave Titanium Booster Gain Gboost (0.6x–2.5x) and Stepped/Catenoidal Sonotrode Horn Gain Ghorn (1.2x–3.0x) into **Horn Face Zero-to-Peak Amplitude A0-p = A_0 * Gboost * Ghorn** (Peak-to-Peak = 2 * A0-p um) and **Peak Vibrational Velocity vmax = 2 * PI() * (f * 1,000) * (A0-p * 10^{-6}) (m/s). Concentrating A0-p into a molded triangular Energy-Director Rib of Effective Height hrib (mm) and Active Melt-Zone Volume Ved (mm³) imposes Cyclic Strain epsilon_0 = (A0-p / 1,000) / hrib, generating Internal Hysteretic Loss Power Pvisc = PI() * (f * 1,000) * (E’’ * 10^6) * epsilon_0^2 * (Ved * 10^{-9})** (W, where Polymer Loss Modulus E’’ = E’ * tan(delta) MPa).

Verify on a 20 kHz Semi-Crystalline Polypropylene / PC-ABS Medical Filter Housing Weld—Converter_Zero-to-Peak A_0 = 10.0 um (B2), Gold_Booster_Gain Gboost = 1.50 (B3), Stepped_Titanium_Horn_Gain Ghorn = 2.20 (B4 -> 66.0 um Peak-to-Peak in E2), Frequency f = 20.0 kHz (B5 -> Tip Velocity = 4.15 m/s in E3), Polymer_Loss_Modulus E’’ = 285 MPa (B6), Energy-Director_Zone Ved = 48.0 mm³ (B7), and Rib_Height hrib = 0.85 mm (B8): Cyclic Strain hits 0.0388 (E4) and Viscoelastic Melt Power delivers a rapid 1,295.6 W (0.25-s weld cycle. E5).

20 kHz Ultrasonic Stack KPI (A0=10 um, Epp=285 MPa, Ved=48 mm³, h=0.85 mm)FormulaVerified Output
Horn Peak-to-Peak Amplitude (um)2 * A0_um * Booster_Gain * Horn_Gain66.0 um p-p (24.0 um p-p @ 1.0x/1.2x stack)
Peak Sonotrode Tip Velocity (m/s)2 * PI() * (f_kHz * 1000) * (A0p_um * 1e-6)4.15 m/s (1.51 m/s @ low-gain stack)
Energy-Director Strain eps0(A0p_um / 1000) / Rib_Height_mm0.0388 (0.0141 @ low-gain stack)
Viscoelastic Heating Power (W)PI() * f_Hz * Epp_Pa * eps0^2 * Ved_m31,295.6 W (171.3 W stalls unmelted)

Acoustic Stack Gain Cascade & Dynamic Loss-Modulus Hysteretic Power Formula

Validate Converter A_0 in [3, 25] um, Gains Gboost, Ghorn in [0.4, 4.0], Frequency f in [15, 70] kHz, Loss_Modulus E’’ in [20, 1,500] MPa, Volume Ved > 1 mm³, and Rib_Height hrib in [0.2, 3.0] mm.

=LET(az_u, B2, gb_x, B3, gh_x, B4, fk_h, B5, ep_m, B6, vd_m, B7, hr_m, B8, ap_u, az_u * gb_x * gh_x, es_z, (ap_u / 1000) / hr_m, IF(OR(az_u < 3, az_u > 25, gb_x < 0.4, gb_x > 4, gh_x < 0.4, gh_x > 4, fk_h < 15, fk_h > 70, ep_m < 20, ep_m > 1500, vd_m <= 1, hr_m < 0.2, hr_m > 3), "Invalid Ultrasonic Stack", ROUND(PI() * (fk_h * 1000) * (ep_m * 1000000) * (es_z ^ 2) * (vd_m * 0.000000001), 1)))

Under-Driven 1:1 Green Booster + 1.2x Block Horn Cold-Collapse Check (Set B3 = 1.0, B4 = 1.2)

Mount a 1.0x booster and 1.2x large-face block horn (B3 = 1.0, B4 = 1.2): Peak-to-Peak Amplitude E2 drops from 66.0 to 24.0 um (2.75x lower), which SQUARES (2.75^2 = 7.56x) to collapse Viscoelastic Heating Power E5 from 1,295.6 down to 171.3 W—cold-mashing the energy director flat before reaching polymer melt temperature.

=IF(ISTEXT(E5), E5, LET(ap_u, B2 * B3 * B4, ROUND(2 * PI() * (B5 * 1000) * (ap_u * 0.000001), 2)))

Try the example

Use the original values or change them to test your understanding.