Arte SheetsLearn. Try. Understand.

Polymer Sheet Processing, Vacuum/Pressure Thermoforming & Packaging Gauge Thinning

Vacuum Thermoforming Areal Draw Ratio & Wall Formula

Calculate Rectangular Mold Areal Draw Ratio Ra = A_mold / A_clamp, Volume-Conserved Average Part Wall Thickness t_avg (mm), Deepest Bottom-Corner Minimum Wall (mm), and Retained Corner Gauge (%).

Drawing a 4.5 mm ABS sheet into a deep tub thins average walls to 1.64 mm—and female mold corners down to 0.90 mm without plug-assist

During single-sheet vacuum or pressure thermoforming, a heated thermoplastic sheet (ABS, PETG, HDPE, HIPS) of Initial Extruded Gauge t_0 (mm) is locked around Clamping-Frame Footprint A_clamp = L * W (mm²) and stretched pneumatically against a 3D mold surface of Total Developed Area A_mold = L * W + 2 * (L + W) * H (mm² for a rectangular tub of depth H). Because solid/rubbery polymer volume inside the clamp frame is strictly conserved (A_clamp * t_0 = A_mold * t_avg), **Areal Draw Ratio R_a = A_mold / A_clamp = 1 + (2 * (L + W) * H) / (L * W) divides starting gauge down to Mean Formed Wall t_avg = t_0 / R_a**. Worse yet, sheet touching the cold mold walls first freezes immediately while the remaining free bubble stretches into deep female corners—leaving Minimum Corner Gauge t_corner = c_f * t_avg (c_f ≈ 0.45–0.65 straight vacuum vs 0.75+ syntactic-foam plug-assist).

Verify on a 400 x 300 x 150 mm ABS Medical-Tray Female Mold—Clamp_Length L = 400.0 mm (B2), Clamp_Width W = 300.0 mm (B3), Cavity_Draw_Depth H = 150.0 mm (B4 -> Areal Draw Ratio R_a = 2.750 in E2), Starting_Sheet_Gauge t_0 = 4.50 mm (B5 -> Mean Part Wall t_avg = 1.64 mm in E3), and Corner_Distribution_Factor c_f = 0.55 (B6): Thinnest Bottom-Corner Gauge equals 0.90 mm (E4 = 20.0% of starting sheet thickness in E5).

Vacuum Thermoforming KPI (400x300 mm Clamp, Depth H=150 mm, t0=4.50 mm, cf=0.55)FormulaVerified Output
Areal Draw Ratio Ra (Amold / Aclamp)1 + (2 * (L_mm + W_mm) * H_mm) / (L * W)2.750 (3.917 @ deep 250 mm tub)
Volume-Conserved Mean Wall (mm)Starting_Gauge_t0_mm / Areal_Draw_Ra1.64 mm (1.15 mm @ deep 250 mm tub)
Minimum Bottom-Corner Wall (mm)Mean_Wall_mm * Corner_Factor_cf0.90 mm (0.63 mm paper-thin @ 250 mm)
Retained Corner Gauge (%)(Corner_Wall_mm / Starting_t0_mm) * 10020.0% (14.0% @ deep 250 mm tub)

Incompressible Sheet Areal Draw Ratio & Corner Wall-Thinning Formula

Validate Clamp_Length L > 10 mm, Clamp_Width W > 10 mm, Draw_Depth H > 0 mm, Starting_Gauge t_0 > 0.1 mm, and Corner_Factor c_f in (0.15, 1.0].

=LET(ln_m, B2, wd_m, B3, ht_m, B4, tz_m, B5, cf_r, B6, ad_r, 1 + (2 * (ln_m + wd_m) * ht_m) / (ln_m * wd_m), tc_m, (tz_m / ad_r) * cf_r, IF(OR(ln_m <= 10, wd_m <= 10, ht_m <= 0, tz_m <= 0.1, cf_r <= 0.15, cf_r > 1), "Invalid Thermoforming Input", ROUND((tc_m / tz_m) * 100, 1)))

Deep-Draw 250 mm Tote Bin Corner Webbing/Tearing Check (Set Cavity Depth H B4 = 250.0 mm)

Deepen the mold cavity from 150.0 to 250.0 mm (B4 = 250): Areal Draw Ratio E2 jumps to 3.917, Average Wall E3 drops to 1.15 mm, and Unassisted Bottom Corners E4 thin down to 0.63 mm (14.0% retained in E5)—confirming why R_a > 3.0 requires syntactic-foam plug-assist pre-stretching or starting gauge t_0 >= 6.0 mm.

=IF(ISTEXT(E5), E5, LET(ad_r, 1 + (2 * (B2 + B3) * B4) / (B2 * B3), ROUND((B5 / ad_r) * B6, 2)))

Try the example

Use the original values or change them to test your understanding.