Industrial Air-Pollution Control & Sub-Micron Scrubbing, Calvert (1970) Venturi Scrubber
Venturi Wet Scrubber Calvert Pressure Drop & Fan Power
Calculate Venturi Throat Gas Velocity (m/s), Liquid-to-Gas Contacting Ratio L/G (L/m³), Calvert Momentum-Transfer Pressure Drop (kPa), and Induced-Draft Fan Shaft Power (kW).
Pinching a variable-throat Venturi scrubber damper from 0.16 to 0.11 m² to trap sub-micron fume boosts L/G + throat velocity—TRIPLING ID-fan power from 137 kW to 426 kW
High-Energy Venturi Wet Particulate Scrubbers capture sticky, hot, or pyrophoric < 1.0-um foundry cupola, BOF steel, and kiln fumes by accelerating dirty gas (Volumetric Flow Q_g m³/s) through a converging Throat Cross-Section A_t (m²) to v_t = Q_g / A_t = 60–120 m/s, shearing injected Scrubbing Liquor Q_L (L/s -> Liquid-to-Gas Ratio L / G = Q_L / Q_g L/m³) into 50-um target droplets for inertial impaction. Seymour Calvert (1970) proved that practically all throat static-pressure loss pays to accelerate stationary liquid mass up to ~85% of gas throat velocity, giving **Calvert Venturi Pressure Drop Delta_P = 0.00102 * (v_t^2) * (L / G) (kPa, ~76 cm H_2O at 7.47 kPa) and Induced-Draft (ID) Fan Shaft Power Pfan = (Q_g * Delta_P) / (etafan / 100)** (kW).
Verify on a Cupola Furnace Adjustable-Damper Venturi Scrubber—Saturated_Gas_Flow Q_g = 12.5 m³/s (45,000 m³/h, B2), Venturi_Throat_Area A_t = 0.16 m² (B3), Scrubbing_Liquor_Rate Q_L = 15.0 L/s (B4), and Wet-Wheel_ID_Fan_Efficiency etafan = 68.0% (B5): Throat Gas Velocity equals 78.1 m/s (E2), Liquid-to-Gas Ratio L / G equals 1.20 L/m³ (E3), Calvert Pressure Drop equals 7.47 kPa (30.0 in. w.g., E4), demanding 137.3 kW of ID-fan shaft power (E5).
| Calvert (1970) Venturi Scrubber KPI (Qg=12.5 m³/s, ID Fan Eff=68%) | Formula | Verified Output |
|---|---|---|
| Throat Gas Velocity vt (m/s) | Gas_Flow_m3_s / Throat_Area_At_m2 | 78.1 m/s (113.6 m/s sub-micron fume trim) |
| Liquid-to-Gas Ratio L/G (L/m³) | Liquor_Flow_L_s / Gas_Flow_m3_s | 1.20 L/m³ (1.76 L/m³ high-wash) |
| Calvert Pressure Drop dP (kPa) | 0.00102 * (Throat_vt_m_s ^ 2) * L_Over_G | 7.47 kPa (23.18 kPa = 93 in. w.g.) |
| ID Fan Shaft Power (kW) | (Gas_Flow_m3_s * dP_kPa) / (Fan_Eff_Pct / 100) | 137.3 kW (426.1 kW = 3.1x motor load) |
Seymour Calvert (1970) Droplet-Acceleration Venturi Pressure Drop & Power Formula
Validate Gas_Flow Q_g in [0.2, 500] m³/s, Throat_Area A_t in [0.005, 10.0] m² (with v_t in [20, 160] m/s), Liquor_Flow Q_L in [0.1, 1,500] L/s (with L/G in [0.3, 5.0] L/m³), and Fan_Efficiency in [40, 88]%.
=LET(qg_s, B2, at_m, B3, ql_s, B4, ef_p, B5, vt_s, qg_s / at_m, lg_r, ql_s / qg_s, dp_k, 0.00102 * (vt_s ^ 2) * lg_r, IF(OR(qg_s < 0.2, qg_s > 500, at_m < 0.005, at_m > 10, vt_s < 20, vt_s > 160, ql_s < 0.1, ql_s > 1500, lg_r < 0.3, lg_r > 5, ef_p < 40, ef_p > 88), "Invalid Venturi Input", ROUND((qg_s * dp_k) / (ef_p / 100), 1)))Sub-Micron Zinc-Oxide Opacity Trim (A_t = 0.11 m², Q_L = 22 L/s) Motor-Overload Check
Pinch throat damper blades down to B3 = 0.11 m² (113.6 m/s in E2) and boost recycle spray to B4 = 22.0 L/s (L / G = 1.76 L/m³ in E3) to pass a 0.3-um opacity stack test: Calvert Delta_P E4 surges 3.1x to 23.18 kPa (93 inches H_2O), driving ID-Fan Shaft Power E5 from 137.3 up to 426.1 kW.
=IF(ISTEXT(E5), E5, ROUND(0.00102 * ((B2 / B3) ^ 2) * (B4 / B2), 2))Try the example
Use the original values or change them to test your understanding.