Occupational Health, Industrial Hygiene & Sports Medicine (ISO 7243)
Wet-Bulb Globe Temperature (WBGT): Indoor and Outdoor Arithmetic
Calculate example WBGT values from natural wet-bulb, globe and air temperatures, and understand why a heat-safety assessment needs more than a single number.
What WBGT combines
Wet-bulb globe temperature combines measurements from a natural wet-bulb thermometer and a globe thermometer; the direct-sun formula also uses dry-bulb air temperature. These measurements reflect environmental heat factors including humidity, radiant heat and air movement. A natural wet-bulb measurement is not automatically the same as a weather app’s heat index or a psychrometric wet-bulb estimate.
With direct solar radiation, WBGT = 0.7 × natural wet-bulb + 0.2 × globe + 0.1 × dry-bulb. Indoors or without solar radiation, WBGT = 0.7 × natural wet-bulb + 0.3 × globe. OSHA recommends a properly used, calibrated WBGT meter at the work location; weather-station readings may differ from actual conditions.
| Illustrative measurements (°C) | Arithmetic | WBGT (°C) |
|---|---|---|
| Natural wet-bulb 24; globe 38; dry-bulb 33; direct sun | 0.7 × 24 + 0.2 × 38 + 0.1 × 33 | 27.70 |
| Natural wet-bulb 24; globe 38; no direct solar radiation | 0.7 × 24 + 0.3 × 38 | 28.20 |
Calculate environmental WBGT
Enter natural wet-bulb temperature in B2, globe temperature in B3, dry-bulb temperature in B4 and sunlight flag in B5 (1 for direct solar radiation, 0 for no solar radiation). Enter this formula in B7. All temperatures use °C. The dry-bulb value is required for the direct-sun formula but not for the no-sun formula.
=IF(COUNT(B2:B3,B5)<>3,"Enter numeric wet-bulb, globe and sunlight flag",IF(AND(B5<>0,B5<>1),"Check sunlight flag",IF(B5=1,IF(COUNT(B4)<>1,"Enter dry-bulb temperature",0.7*B2+0.2*B3+0.1*B4),0.7*B2+0.3*B3)))Display the environmental result
This rounds the numerical teaching example to two decimals. Basic numeric checks do not verify that instruments are correctly calibrated or placed.
=IF(ISNUMBER(B7),ROUND(B7,2),B7)Illustrate a clothing adjustment
If a qualified assessment supplies an applicable clothing adjustment in °C, enter it in B6 and add it to environmental WBGT. A value of 2 in the example is hypothetical; it does not specify an adjustment for a particular garment or establish a safe exposure. Some protective ensembles may require a different assessment.
=IF(ISNUMBER(B7),IF(COUNT(B6)<>1,"Enter numeric adjustment",IF(B6<0,"Check adjustment",ROUND(B7+B6,2))),B7)A calculation is not a work–rest schedule
Do not choose continuous work or a work–rest cycle from these formulas alone. OSHA and NIOSH consider workload, acclimatization, clothing, environmental conditions and individual factors; rest duration and cooling conditions also matter. Use the applicable workplace heat-safety plan and qualified assessment, including water, rest, cooling and monitoring.
Try the example
Use the original values or change them to test your understanding.