Indirect calorimetry and the Weir equation

Indirect calorimetry uses oxygen consumption (VO₂) and carbon dioxide production (VCO₂) to estimate energy expenditure. Weir’s 1949 work described a relation involving gas exchange and urinary nitrogen. When rates are entered in mL/min and total urinary nitrogen in g/day, the example uses 1.44 × (3.941 × VO₂ + 1.106 × VCO₂) − 2.17 × nitrogen for kcal/day.

The factor 1.44 combines conversion from mL to liters with 1,440 minutes per day. Many practical calculations omit the nitrogen term; that is a different approximation, not a measurement of zero nitrogen. The nitrogen in the full relation is total urinary nitrogen, and urinary urea nitrogen alone is not necessarily identical.

Extrapolating a short measurement to a day assumes conditions represented by the measurement. Calling the result resting energy expenditure requires appropriate resting and measurement conditions; clinical nutrition decisions should not rely on this unvalidated example alone.

Abbreviated calculation

Enter positive fictional oxygen consumption B2 and carbon dioxide production B3 in mL/min. This form does not require a urinary nitrogen measurement and explicitly omits its correction.

=IF(COUNT(B2:B3)<>2,"Enter both numeric gas rates",IF(OR(B2<=0,B3<=0),"Enter positive gas rates",ROUND(1.44*(3.941*B2+1.106*B3),1)))

Calculate with a nitrogen term

Enter total urinary nitrogen in g/day in B4. This form requires all three inputs; a missing nitrogen measurement is not treated as zero. Urinary urea nitrogen is only part of total urinary nitrogen and should not be silently substituted.

=IF(COUNT(B2:B4)<>3,"Enter gas rates and total urinary nitrogen",IF(OR(B2<=0,B3<=0,B4<0),"Check gas rates and nitrogen",IF(1.44*(3.941*B2+1.106*B3)-2.17*B4<0,"Review nitrogen and gas inputs",ROUND(1.44*(3.941*B2+1.106*B3)-2.17*B4,1))))

Measured gas-exchange ratio

The observed VCO₂ / VO₂ ratio is often called respiratory exchange ratio (RER). It can approximate the tissue respiratory quotient under suitable steady-state conditions, but an unusual ratio alone does not prove a leak, overfeeding, or a particular substrate mix. The two gas measurements and test conditions need professional review.

=IF(COUNT(B2:B3)<>2,"Enter both numeric gas rates",IF(OR(B2<=0,B3<=0),"Enter positive gas rates",ROUND(B3/B2,3)))

Try the example

Use the original values or change them to test your understanding.